Specifications
SKU: 9226194
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Forward Voltage | VF | IF = 20 mA | 1.1 | 1.3 | 1.6 | V |
Reverse Breakdown Voltage | VBR | IR = 1 mA | - | - | -5 | V |
Reverse Leakage Current | IR | VR = -5 V | - | 100 | - | nA |
Output High Voltage | VOH | IOH = -1 mA, VCC = 5 V | 4.5 | - | 5.5 | V |
Output Low Voltage | VOL | IOL = 16 mA, VCC = 5 V | - | 0.4 | - | V |
Propagation Delay Time | tpd | VCC = 5 V, IF = 20 mA, VO = 2.5 V | - | 250 | - | ns |
Rise Time | tr | VCC = 5 V, IF = 20 mA, VO = 2.5 V | - | 200 | - | ns |
Fall Time | tf | VCC = 5 V, IF = 20 mA, VO = 2.5 V | - | 200 | - | ns |
Common-Mode Transient Immunity | CMTI | VCC = 5 V, IF = 20 mA | - | 25 | - | kV/μs |
Instructions for HCPL4503SDM
Power Supply (VCC):
- Ensure the supply voltage is within the specified range (4.5 V to 5.5 V) to avoid damage to the device.
- Use a stable power supply to maintain consistent operation.
Forward Current (IF):
- The forward current should be set to 20 mA for optimal performance.
- Exceeding the maximum forward current can lead to overheating and potential failure.
Reverse Voltage (VR):
- The reverse voltage should not exceed -5 V to prevent breakdown and damage to the device.
Output Load:
- For high output (VOH), ensure the load current does not exceed -1 mA.
- For low output (VOL), ensure the load current does not exceed 16 mA.
Timing Parameters:
- The propagation delay time (tpd), rise time (tr), and fall time (tf) are critical for timing-sensitive applications.
- Ensure these parameters meet the requirements of your system to avoid data corruption or timing issues.
Common-Mode Transient Immunity (CMTI):
- The device has a CMTI of 25 kV/μs, which indicates its ability to handle fast transient voltages.
- Design the circuit to minimize common-mode transients to ensure reliable operation.
Handling and Storage:
- Handle the device with care to avoid static discharge and physical damage.
- Store the device in a dry, cool place to prevent moisture-related issues.
Mounting and Soldering:
- Follow recommended soldering profiles to avoid thermal stress.
- Ensure proper mechanical support to prevent strain on the leads.
Testing:
- Test the device under typical operating conditions to verify correct functionality.
- Use appropriate test equipment to measure key parameters such as forward voltage, output voltages, and timing characteristics.
By following these instructions, you can ensure the reliable and efficient operation of the HCPL4503SDM optical isolator.
(For reference only)Inquiry - HCPL4503SDM