Share:


MPKB2CA150U60

Specifications

SKU: 9253210

BUY MPKB2CA150U60 https://www.utsource.net/itm/p/9253210.html

Parameter Symbol Min Typ Max Unit Description
Input Voltage VIN 27 - 60 V Operating input voltage range
Output Voltage VOUT 0.8 - 15 V Adjustable output voltage range
Output Current IOUT - - 2 A Maximum continuous output current
Efficiency η - 93 - % Typical efficiency at nominal conditions
Switching Frequency fSW - 650 - kHz Nominal switching frequency
Quiescent Current IQ - 40 - μA Quiescent current at no load
Dropout Voltage VDROPOUT - 1.2 - V Dropout voltage at full load
Load Regulation ΔVOUT/ΔIOUT - 0.5 - % Load regulation over full load range
Line Regulation ΔVOUT/ΔVIN - 0.1 - %/V Line regulation over full input range
Ripple Voltage VRIPPLE - 20 - mV Output ripple voltage at full load
Start-up Time tSTART - 5 - ms Time to reach regulation after power-on
Short-Circuit Current ISC - 3 - A Maximum short-circuit current
Operating Temperature TOPR -40 - 125 °C Operating temperature range
Storage Temperature TSTG -55 - 150 °C Storage temperature range

Instructions for Use:

  1. Input Voltage (VIN):

    • Ensure the input voltage is within the specified range (27V to 60V) to avoid damage to the device.
  2. Output Voltage (VOUT):

    • Adjust the output voltage using the external resistor network as per the datasheet guidelines.
  3. Output Current (IOUT):

    • The device can provide up to 2A of continuous output current. Ensure the load does not exceed this limit to prevent overheating or damage.
  4. Efficiency (η):

    • The typical efficiency is 93% under nominal conditions. Monitor the power dissipation to ensure it remains within safe limits.
  5. Switching Frequency (fSW):

    • The nominal switching frequency is 650kHz. This can be adjusted if necessary, but check the impact on efficiency and performance.
  6. Quiescent Current (IQ):

    • The quiescent current is typically 40μA at no load. This is important for low-power applications.
  7. Dropout Voltage (VDROPOUT):

    • The dropout voltage is 1.2V at full load. Ensure the input voltage is sufficiently higher than the output voltage to maintain regulation.
  8. Load Regulation (ΔVOUT/ΔIOUT):

    • The load regulation is 0.5% over the full load range. This ensures stable output voltage under varying load conditions.
  9. Line Regulation (ΔVOUT/ΔVIN):

    • The line regulation is 0.1%/V over the full input range. This helps maintain a stable output voltage with changes in input voltage.
  10. Ripple Voltage (VRIPPLE):

    • The output ripple voltage is typically 20mV at full load. Use appropriate filtering if lower ripple is required.
  11. Start-up Time (tSTART):

    • The time to reach regulation after power-on is typically 5ms. This is important for systems that require quick start-up.
  12. Short-Circuit Current (ISC):

    • The maximum short-circuit current is 3A. The device will automatically shut down to protect itself from damage.
  13. Operating Temperature (TOPR):

    • The operating temperature range is -40°C to 125°C. Ensure the device is used within this range to avoid thermal stress.
  14. Storage Temperature (TSTG):

    • The storage temperature range is -55°C to 150°C. Store the device in a suitable environment to prevent damage.

For detailed application notes and specific design considerations, refer to the datasheet provided by the manufacturer.

(For reference only)

 Inquiry - MPKB2CA150U60