Parameter Description Value
Package Type Encapsulation LQFP-80
Operating Temperature Range Temperature range for operation -40°C to +85°C
Supply Voltage (VDD) Operating voltage range 2.7V to 5.25V
Analog Input Range Range of analog input voltages 0V to VREF
Resolution Number of bits 16 bits
Sampling Rate Maximum sampling rate 250 kSPS (kilo samples per second)
Differential Inputs Number of differential inputs 8 channels
Input Impedance Input impedance High (typically >10 MΩ)
Power Consumption Typical power consumption at 3.3V, 250 kSPS 125 mW
Interface Digital interface type SPI, SDI, SDO
Package Size Dimensions 14 mm x 14 mm x 1.4 mm
Lead Pitch Distance between leads 0.5 mm
Weight Approximate weight 2.5 g

Instructions for Use:

  1. Power Supply:

    • Connect the VDD pin to a stable power supply within the specified range (2.7V to 5.25V).
    • Connect the GND pin to the system ground.
  2. Analog Inputs:

    • Connect the analog signals to the differential input pairs (AIN0 to AIN7).
    • Ensure the input voltages do not exceed the specified range (0V to VREF).
  3. Reference Voltage:

    • Connect the reference voltage (VREF) to a stable reference source.
    • The reference voltage should be within the range of 2.5V to 5V.
  4. Digital Interface:

    • Connect the SPI interface pins (SDI, SDO, SCLK) to the corresponding pins on your microcontroller or digital system.
    • Configure the SPI settings according to the datasheet specifications.
  5. Grounding:

    • Ensure proper grounding to minimize noise and interference.
    • Use a star grounding technique if multiple grounds are involved.
  6. Decoupling Capacitors:

    • Place decoupling capacitors (0.1 μF and 10 μF) close to the VDD and GND pins to filter out high-frequency noise.
  7. Configuration:

    • Use the configuration registers to set up the ADC according to your application requirements (e.g., channel selection, conversion mode).
  8. Data Acquisition:

    • Initiate conversions by writing to the control register.
    • Read the converted data from the output register using the SPI interface.
  9. Handling:

    • Handle the device with care to avoid static discharge.
    • Follow ESD (Electrostatic Discharge) precautions during handling and installation.
  10. Storage:

    • Store the device in a dry, cool place away from direct sunlight and moisture.

For detailed information, refer to the AD7616BSTZ datasheet provided by Analog Devices.