Parameter Symbol Min Typ Max Unit Description
Supply Voltage VDD 4.5 - 36 V Operating voltage range
Logic Supply Voltage VLOGIC 1.8 - 5.5 V Logic supply voltage range
Continuous Output Current IOUT - 1.2 2.5 A Continuous output current per channel (with heatsink)
Peak Output Current IPEAK - 2.5 4.5 A Peak output current per channel
Thermal Shutdown TSD - 150 - °C Thermal shutdown temperature
Under-Voltage Lockout UVLO 3.2 - 3.6 V Under-voltage lockout threshold (VDD)
Logic Input High Level VIH 0.7 - VLOGIC V Minimum logic input high level
Logic Input Low Level VIL - 0.3 - V Maximum logic input low level
PWM Frequency FPWM - 200 1000 kHz Recommended PWM frequency
Quiescent Current IQ - 0.9 - mA Quiescent current (all outputs off)
Short-Circuit Protection SCP - - - - Automatic recovery with hysteresis
Thermal Shutdown Hysteresis TSHYS - 15 - °C Thermal shutdown hysteresis
Operating Temperature Range TOPR -40 - 125 °C Operating temperature range
Storage Temperature Range TSTG -65 - 150 °C Storage temperature range

Instructions for Use:

  1. Power Supply:

    • Connect VDD to the power supply within the specified range (4.5V to 36V).
    • Connect VLOGIC to the logic supply within the specified range (1.8V to 5.5V).
  2. Output Configuration:

    • Ensure the continuous output current does not exceed 1.2A per channel without a heatsink, and 2.5A with a heatsink.
    • Do not exceed the peak output current of 4.5A.
  3. Thermal Management:

    • Monitor the device temperature to avoid exceeding the thermal shutdown temperature of 150°C.
    • Use a heatsink if operating at high currents or in high ambient temperatures.
  4. Under-Voltage Lockout:

    • The device will shut down if VDD drops below 3.2V and restart when it rises above 3.6V.
  5. Logic Inputs:

    • Ensure logic inputs are within the specified levels (VIH > 0.7V and VIL < 0.3V).
  6. PWM Control:

    • Use a PWM frequency between 200kHz and 1000kHz for optimal performance.
  7. Protection Features:

    • The device includes short-circuit protection and automatic recovery.
    • Thermal shutdown is activated at 150°C with a hysteresis of 15°C.
  8. Operating and Storage Conditions:

    • Operate the device within the temperature range of -40°C to 125°C.
    • Store the device within the temperature range of -65°C to 150°C.
  9. Handling Precautions:

    • Handle the device with care to avoid damage from electrostatic discharge (ESD).
    • Follow proper soldering and mounting procedures to ensure reliable operation.
(For reference only)

 Inquiry - DRV8848PWPR