Specifications
SKU: 9482028
Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Supply Voltage | VDD | 2.7 | - | 5.5 | V | Operating supply voltage range |
Supply Current | IDD | - | 400 | - | μA | Typical supply current at 3V, 10SPS |
Output Data Rate | ODR | 0.1 | - | 30 | SPS | Configurable output data rate |
Input Range | VIN | - | - | - | V | Differential input voltage range (±2.048V, ±4.096V, ±6.144V, ±8.192V, ±16.384V) |
Resolution | - | 24 | - | bits | Resolution of the ADC | |
Integral Nonlinearity | INL | - | 2 | - | LSB | Integral nonlinearity error |
Differential Nonlinearity | DNL | - | 1 | - | LSB | Differential nonlinearity error |
Offset Error | - | 2 | - | μV | Maximum offset error | |
Gain Error | - | 0.01 | - | % | Maximum gain error | |
Common-Mode Rejection Ratio | CMRR | - | 90 | - | dB | Common-mode rejection ratio at 50/60Hz |
Power-Down Mode Current | IDD PD | - | 1 | - | μA | Current consumption in power-down mode |
Operating Temperature | Toper | -40 | - | 85 | °C | Operating temperature range |
Storage Temperature | Tstg | -40 | - | 125 | °C | Storage temperature range |
Instructions for ADS1251U SOP8
Power Supply:
- Connect the VDD pin to a stable power supply within the range of 2.7V to 5.5V.
- Ensure the GND pin is connected to the system ground.
Input Configuration:
- Connect the differential input signals to the IN+ and IN- pins.
- Choose the appropriate input range by configuring the gain settings via the control register.
Output Data Rate:
- Set the desired output data rate (ODR) through the control register. The available rates are from 0.1 SPS to 30 SPS.
Data Conversion:
- Initiate a conversion by writing to the control register or using the start conversion command.
- Read the conversion result from the data register once the conversion is complete.
Power-Down Mode:
- To reduce power consumption, enter the power-down mode by setting the appropriate bit in the control register.
- The device will consume approximately 1 μA in this mode.
Temperature Considerations:
- Ensure the operating temperature remains within the specified range of -40°C to 85°C.
- Store the device in an environment where the temperature does not exceed 125°C.
Electrostatic Discharge (ESD) Protection:
- Handle the device with care to avoid ESD damage.
- Use proper ESD protection equipment and follow recommended handling procedures.
Layout and Grounding:
- Use a solid ground plane and keep signal traces as short as possible to minimize noise.
- Place decoupling capacitors close to the VDD and GND pins to ensure stable operation.
Communication Interface:
- The device supports SPI communication. Ensure the clock frequency and data format are correctly configured according to the datasheet specifications.
Calibration:
- Perform initial calibration to correct for offset and gain errors. This can be done using the built-in calibration features or external methods.
By following these instructions, you can effectively integrate the ADS1251U SOP8 into your design and achieve optimal performance.