Share:


BM08B-SRSS-TB(LF)(SN)

Specifications

SKU: 9482129

BUY BM08B-SRSS-TB(LF)(SN) https://www.utsource.net/itm/p/9482129.html

Parameter Description Value
Part Number Full part number BM08B-SRSS-TB(LF)(SN)
Manufacturer Company that produces the component Panasonic
Type Component category Surface Mount Relay
Coil Voltage Voltage required to activate the relay 5V DC
Coil Current Current drawn by the coil when activated 32mA
Contact Form Configuration of the relay contacts SPDT (Single Pole Double Throw)
Contact Rating Maximum current and voltage the contacts can handle 5A, 125V AC / 30V DC
Insulation Resistance Resistance between the coil and contacts 100MΩ min at 250V DC
Dielectric Strength Voltage the insulation can withstand without breakdown 1500V AC for 1 minute
Operating Temperature Range of temperatures the relay can operate in -40°C to +85°C
Storage Temperature Range of temperatures the relay can be stored in -40°C to +85°C
Mechanical Life Number of operations before failure 10 million cycles
Electrical Life Number of operations under rated load before failure 100,000 cycles
Terminal Type Type of terminals used for connections Soldering Pads
Package Size Dimensions of the component 8.0 x 8.0 x 6.2 mm
Weight Mass of the component 0.7g

Instructions:

  1. Handling:

    • Handle with care to avoid damage to the component.
    • Use appropriate ESD (Electrostatic Discharge) precautions to prevent damage.
  2. Soldering:

    • Preheat the PCB to 100-120°C before soldering.
    • Soldering temperature should not exceed 260°C.
    • Soldering time should not exceed 10 seconds per pad.
  3. Mounting:

    • Ensure the relay is securely mounted on the PCB.
    • Avoid applying excessive force or torque during installation.
  4. Testing:

    • Test the relay after installation to ensure proper operation.
    • Verify the contact resistance and insulation resistance meet the specified values.
  5. Operation:

    • Apply the correct coil voltage to activate the relay.
    • Do not exceed the maximum contact ratings to prevent damage or failure.
    • Regularly inspect the relay for signs of wear or damage.
  6. Storage:

    • Store in a dry, cool place away from direct sunlight.
    • Keep the relay in its original packaging until ready for use.
(For reference only)