Specifications
SKU: 9513615
Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Input Voltage (Gate to Source) | Vgs | -20 | 12 | V | ||
Drain-Source Breakdown Voltage | Vds | 600 | V | |||
Continuous Drain Current | Id | 45 | A | Tc = 25°C | ||
Power Dissipation | Ptot | 200 | W | Tc = 25°C | ||
Junction Temperature | Tj | -55 | 175 | °C | ||
Storage Temperature | Tstg | -55 | 150 | °C | ||
Gate Charge | Qg | 120 | nC | Vgs = 15V | ||
Total Gate Charge | Qgt | 140 | nC | Vgs = 15V | ||
Input Capacitance | Ciss | 3400 | pF | Vds = 25V | ||
Output Capacitance | Coss | 1100 | pF | Vds = 25V | ||
Reverse Transfer Capacitance | Crss | 1200 | pF | Vds = 25V | ||
Turn-On Delay Time | tdon | 45 | ns | Vgs = 15V, Id = 45A | ||
Rise Time | tr | 25 | ns | Vgs = 15V, Id = 45A | ||
Turn-Off Delay Time | tdoff | 20 | ns | Vgs = -9V, Id = 45A | ||
Fall Time | tf | 15 | ns | Vgs = -9V, Id = 45A |
Instructions for Use:
Mounting and Handling:
- Ensure proper heat sinking to manage power dissipation and junction temperature.
- Handle with care to avoid static damage; use ESD protection.
Biasing and Operation:
- Apply gate voltage within the specified range to avoid damage.
- Ensure the drain-source voltage does not exceed the breakdown voltage.
- Operate within the continuous drain current limits to prevent overheating.
Thermal Management:
- Monitor junction temperature to ensure it stays within the safe operating range.
- Use appropriate cooling methods such as heatsinks or forced air cooling.
Testing and Measurement:
- Use recommended test conditions for accurate parameter measurements.
- Ensure all connections are secure and free from oxidation or contamination.
Storage:
- Store in a dry, cool place away from direct sunlight.
- Follow recommended storage temperature limits to maintain component integrity.
Soldering:
- Use a controlled soldering process to avoid thermal shock.
- Follow manufacturer guidelines for soldering temperature and time.
Safety:
- Always follow safety guidelines when handling high-voltage components.
- Use appropriate personal protective equipment (PPE) during assembly and testing.
Inquiry - IRG7IC28U