Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating 4.5 5.0 5.5 V
Output Current (per channel) IO Continuous - 100 - mA
Operating Temperature TOPR Storage -40 - 85 °C
Storage Temperature TSTG Storage -55 - 150 °C
Output Voltage Swing VOS No Load 0 - 0.3 V
Input Voltage Range VIN Operating 0 - 5.5 V
Quiescent Current IQ All outputs off - 0.1 1 mA
Propagation Delay Time tPD High to Low - 20 50 ns
Output Rise Time tR 15pF load - 10 30 ns
Output Fall Time tF 15pF load - 10 30 ns
Maximum Power Dissipation PD TA = 25°C - - 625 mW

Instructions for Using UPD63200GS

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 4.5V to 5.5V.
    • Use a stable power source to avoid voltage fluctuations that can affect performance.
  2. Output Current:

    • Each output channel can handle up to 100mA continuously.
    • Avoid exceeding this limit to prevent damage to the device.
  3. Temperature Considerations:

    • The operating temperature range is from -40°C to 85°C.
    • The storage temperature range is from -55°C to 150°C.
    • Ensure the device is used within these limits to maintain reliability.
  4. Output Voltage Swing:

    • The output voltage swing is typically 0.3V under no load conditions.
    • This value can help in designing the load circuitry to ensure proper operation.
  5. Input Voltage Range:

    • The input voltage should be between 0V and 5.5V.
    • Exceeding these limits can cause damage or improper operation.
  6. Quiescent Current:

    • The quiescent current is typically 0.1mA when all outputs are off.
    • This value is important for low-power applications.
  7. Propagation Delay Time:

    • The propagation delay time from high to low is typically 20ns with a maximum of 50ns.
    • This is crucial for timing-sensitive applications.
  8. Output Rise and Fall Times:

    • The output rise and fall times are typically 10ns with a maximum of 30ns for a 15pF load.
    • These values help in designing the output circuitry to minimize signal distortion.
  9. Maximum Power Dissipation:

    • The maximum power dissipation at 25°C ambient temperature is 625mW.
    • Ensure adequate heat sinking or cooling if the device is expected to dissipate significant power.
  10. Handling and Storage:

    • Handle the device with care to avoid static discharge.
    • Store the device in a dry, cool place within the specified storage temperature range.

By following these parameters and instructions, you can ensure the optimal performance and longevity of the UPD63200GS.