Specifications
SKU: 9523530
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VCC | - | 2.7 | - | 5.5 | V |
Output Voltage (High) | VOH | IL = -10 mA | - | 4.5 | 5.0 | V |
Output Voltage (Low) | VOL | IL = 16 mA | 0.2 | - | 0.4 | V |
Quiescent Current | IQ | - | - | 10 | 20 | μA |
Magnetic Sensitivity | SB | BR to BOP | - | 1.3 | 2.7 | mV/Gauss |
Operating Temperature Range | TA | - | -40 | - | 150 | °C |
Storage Temperature Range | TSTG | - | -65 | - | 150 | °C |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 2.7V to 5.5V.
- Connect the VCC pin to the positive power supply and GND to the ground.
Output Configuration:
- The output is open-drain, requiring a pull-up resistor to a suitable voltage level (typically VCC).
- The output will be high (VOH) when no magnetic field is detected and low (VOL) when a magnetic field is detected.
Magnetic Sensitivity:
- The device has a sensitivity range from 1.3 mV/Gauss to 2.7 mV/Gauss. Adjust the magnetic field strength accordingly to ensure reliable operation.
Temperature Considerations:
- Operate the device within the temperature range of -40°C to 150°C to ensure proper performance.
- Store the device within the storage temperature range of -65°C to 150°C.
Quiescent Current:
- The quiescent current (IQ) is typically 10 μA and can go up to 20 μA. This should be considered in low-power applications.
Handling and Installation:
- Handle the device with care to avoid static damage.
- Ensure proper soldering and mounting to prevent mechanical stress on the pins.
Testing and Troubleshooting:
- Test the device by applying a known magnetic field and verifying the output state.
- If the output does not change as expected, check the power supply, connections, and magnetic field strength.
Inquiry - A1309