Specifications
SKU: 9523987
Parameter | Symbol | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Drain-Source Voltage | VDS | - | - | 600 | V |
Gate-Source Voltage | VGS | -20 | - | 20 | V |
Continuous Drain Current | ID | - | 13 | - | A |
Pulse Drain Current (tp=10ms) | ID(tp) | - | 52 | - | A |
Gate-Threshold Voltage | VGS(th) | 2.0 | 4.0 | 6.0 | V |
On-State Resistance (VGS=10V) | RDS(on) | - | 1.8 | - | Ω |
Input Capacitance | Ciss | - | 2700 | - | pF |
Output Capacitance | Coss | - | 300 | - | pF |
Reverse Transfer Capacitance | Crss | - | 120 | - | pF |
Total Dissipation (TC=25°C) | PTOT | - | 180 | - | W |
Junction Temperature | TJ | -55 | - | 150 | °C |
Storage Temperature | TSTG | -55 | - | 150 | °C |
Instructions for Use:
Handling Precautions:
- Handle the device with care to avoid damage.
- Use proper ESD protection to prevent static discharge.
Mounting:
- Ensure the device is securely mounted to a heat sink to manage thermal dissipation.
- Use thermal paste between the device and the heat sink for better heat transfer.
Electrical Connections:
- Connect the drain (D), source (S), and gate (G) terminals correctly.
- Ensure all connections are secure and free from short circuits.
Operating Conditions:
- Do not exceed the maximum ratings specified in the table.
- Operate within the recommended operating conditions to ensure reliable performance.
Thermal Management:
- Monitor the junction temperature to ensure it stays within safe limits.
- Use appropriate cooling methods such as forced air or liquid cooling if necessary.
Testing:
- Perform initial testing at lower power levels to verify correct operation.
- Gradually increase the load to the desired operating conditions.
Storage:
- Store the device in a dry, cool environment to prevent moisture damage.
- Keep the device in its original packaging until ready for use.