Specifications
SKU: 9530132
Parameter | Symbol | Min | Typical | Max | Unit | Notes |
---|---|---|---|---|---|---|
Drain-Source Voltage | VDS | - | - | 60 | V | |
Gate-Source Voltage | VGS | -20 | - | 20 | V | |
Continuous Drain Current | ID | - | - | 20 | A | @ TC = 25°C |
Pulse Drain Current | ID(p) | - | - | 35 | A | @ TC = 25°C, tp = 10 μs, IGS = 10 A |
Power Dissipation | PD | - | - | 140 | W | @ TC = 25°C |
Junction Temperature | TJ | - | - | 175 | °C | |
Storage Temperature | TSTG | -55 | - | 150 | °C | |
Thermal Resistance, Junction to Case | RθJC | - | 0.7 | - | °C/W | |
Gate Charge | QG | - | 38 | - | nC | |
Input Capacitance | Ciss | - | 1950 | - | pF | @ VDS = 25 V, f = 1 MHz |
Output Capacitance | Coss | - | 450 | - | pF | @ VDS = 25 V, f = 1 MHz |
Reverse Transfer Capacitance | Crss | - | 280 | - | pF | @ VDS = 25 V, f = 1 MHz |
Turn-On Delay Time | td(on) | - | 25 | - | ns | @ ID = 10 A, VGS = 10 V, Rg = 1 Ω |
Rise Time | tr | - | 25 | - | ns | @ ID = 10 A, VGS = 10 V, Rg = 1 Ω |
Turn-Off Delay Time | td(off) | - | 15 | - | ns | @ ID = 10 A, VGS = 10 V, Rg = 1 Ω |
Fall Time | tf | - | 15 | - | ns | @ ID = 10 A, VGS = 10 V, Rg = 1 Ω |
Instructions for Use:
Handling Precautions:
- Handle the TP60N20T with care to avoid damage to the leads and the die.
- Use appropriate ESD (Electrostatic Discharge) protection to prevent damage from static electricity.
Mounting:
- Ensure proper heat sinking to maintain the junction temperature within safe limits.
- Use thermal paste or a thermal pad between the device and the heatsink for better thermal conductivity.
Biasing:
- Apply the gate-source voltage (VGS) carefully to avoid exceeding the maximum ratings.
- Ensure that the gate resistor (Rg) is chosen to provide stable operation and control switching times.
Operation:
- Operate the device within the specified temperature range to ensure reliable performance.
- Monitor the power dissipation to avoid overheating, especially during high current or high-frequency operation.
Storage:
- Store the device in a dry, cool place to prevent moisture damage.
- Keep the device in its original packaging until ready for use to protect it from physical damage and contamination.
Testing:
- Use a suitable test setup to verify the parameters and performance of the device.
- Follow the recommended test conditions to obtain accurate measurements.
Safety:
- Always follow safety guidelines when working with high voltages and currents.
- Ensure that the circuit is properly insulated and grounded to prevent electrical hazards.
Inquiry - TP60N20T