Share:


TP60N20T

Specifications

SKU: 9530132

BUY TP60N20T https://www.utsource.net/itm/p/9530132.html

Parameter Symbol Min Typical Max Unit Notes
Drain-Source Voltage VDS - - 60 V
Gate-Source Voltage VGS -20 - 20 V
Continuous Drain Current ID - - 20 A @ TC = 25°C
Pulse Drain Current ID(p) - - 35 A @ TC = 25°C, tp = 10 μs, IGS = 10 A
Power Dissipation PD - - 140 W @ TC = 25°C
Junction Temperature TJ - - 175 °C
Storage Temperature TSTG -55 - 150 °C
Thermal Resistance, Junction to Case RθJC - 0.7 - °C/W
Gate Charge QG - 38 - nC
Input Capacitance Ciss - 1950 - pF @ VDS = 25 V, f = 1 MHz
Output Capacitance Coss - 450 - pF @ VDS = 25 V, f = 1 MHz
Reverse Transfer Capacitance Crss - 280 - pF @ VDS = 25 V, f = 1 MHz
Turn-On Delay Time td(on) - 25 - ns @ ID = 10 A, VGS = 10 V, Rg = 1 Ω
Rise Time tr - 25 - ns @ ID = 10 A, VGS = 10 V, Rg = 1 Ω
Turn-Off Delay Time td(off) - 15 - ns @ ID = 10 A, VGS = 10 V, Rg = 1 Ω
Fall Time tf - 15 - ns @ ID = 10 A, VGS = 10 V, Rg = 1 Ω

Instructions for Use:

  1. Handling Precautions:

    • Handle the TP60N20T with care to avoid damage to the leads and the die.
    • Use appropriate ESD (Electrostatic Discharge) protection to prevent damage from static electricity.
  2. Mounting:

    • Ensure proper heat sinking to maintain the junction temperature within safe limits.
    • Use thermal paste or a thermal pad between the device and the heatsink for better thermal conductivity.
  3. Biasing:

    • Apply the gate-source voltage (VGS) carefully to avoid exceeding the maximum ratings.
    • Ensure that the gate resistor (Rg) is chosen to provide stable operation and control switching times.
  4. Operation:

    • Operate the device within the specified temperature range to ensure reliable performance.
    • Monitor the power dissipation to avoid overheating, especially during high current or high-frequency operation.
  5. Storage:

    • Store the device in a dry, cool place to prevent moisture damage.
    • Keep the device in its original packaging until ready for use to protect it from physical damage and contamination.
  6. Testing:

    • Use a suitable test setup to verify the parameters and performance of the device.
    • Follow the recommended test conditions to obtain accurate measurements.
  7. Safety:

    • Always follow safety guidelines when working with high voltages and currents.
    • Ensure that the circuit is properly insulated and grounded to prevent electrical hazards.
(For reference only)

 Inquiry - TP60N20T