Specifications
SKU: 9530443
Good quality
Parameter | Symbol | Min | Typical | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Forward Voltage | Vf | 0.8 | 1.0 | 1.2 | V | IF = 50 mA, Ta = 25°C |
Reverse Current | Ir | - | 1.0 | - | μA | VR = 5 V, Ta = 25°C |
Peak Forward Current | Ifsm | - | 1.0 | - | A | t = 10 ms, Ta = 25°C |
Operating Temperature | Topr | -40 | - | 85 | °C | - |
Storage Temperature | Tstg | -65 | - | 150 | °C | - |
Thermal Resistance | Rth | - | 150 | - | K/W | Junction to Ambient |
Instructions for Use:
Mounting:
- Ensure the component is mounted on a clean and flat surface.
- Use appropriate soldering techniques to avoid thermal shock.
Handling:
- Handle the component with care to avoid mechanical damage.
- Use ESD (Electrostatic Discharge) protection when handling to prevent damage from static electricity.
Operating Conditions:
- Ensure the forward current (IF) does not exceed 50 mA to avoid overheating.
- Keep the reverse voltage (VR) below 5 V to prevent breakdown.
- Operate the component within the specified temperature range (-40°C to 85°C).
Storage:
- Store the component in a dry and cool place.
- Avoid exposure to extreme temperatures and humidity.
Testing:
- Use a multimeter or appropriate testing equipment to verify the forward voltage (Vf) and reverse current (Ir).
- Ensure the component is not subjected to peak forward current (Ifsm) for extended periods to prevent damage.
Soldering:
- Preheat the PCB to 100°C to 120°C before soldering.
- Use a soldering iron with a temperature setting between 300°C and 350°C.
- Apply solder for no more than 3 seconds to each joint.
Thermal Management:
- Consider using heat sinks or other cooling methods if the component will be operating near its maximum power dissipation.
- Monitor the junction temperature to ensure it does not exceed the maximum thermal resistance (Rth) limits.
By following these guidelines, you can ensure the optimal performance and longevity of the STTH112U component.