Specifications
SKU: 9739919
Parameter | Symbol | Min | Typical | Max | Unit | Notes |
---|---|---|---|---|---|---|
Maximum Repetitive Peak Reverse Voltage | VRRM | - | 600 | - | V | |
Maximum RMS Voltage (Sinusoidal) | VRMS | - | 424 | - | V | |
Maximum DC Blocking Voltage | VDC | - | 600 | - | V | |
Maximum Average Rectified Output Current (Tc = 100°C) | IORM | - | 20 | - | A | |
Maximum Average Rectified Output Current (Tc = 75°C) | IORM | - | 25 | - | A | |
Maximum Average Rectified Output Current (Tc = 25°C) | IORM | - | 30 | - | A | |
Non-Repetitive Peak Surge Current (8.3/400μs, Tj = 25°C) | IFSM | - | 400 | - | A | |
Non-Repetitive Peak Surge Current (8.3/400μs, Tj = 100°C) | IFSM | - | 300 | - | A | |
Forward Voltage at Rated Current (IF = 20A, Tj = 25°C) | VF | 0.9 | 1.1 | 1.3 | V | |
Forward Voltage at Rated Current (IF = 20A, Tj = 100°C) | VF | 1.1 | 1.3 | 1.5 | V | |
Reverse Recovery Time (IF = 20A, di/dt = 200A/μs) | trr | - | 75 | - | ns | |
Junction to Case Thermal Resistance | RθJC | - | 0.4 | - | °C/W | |
Junction to Ambient Thermal Resistance | RθJA | - | 25 | - | °C/W | |
Operating and Storage Temperature Range | TJ | -55 | - | 150 | °C |
Instructions for Use:
Mounting:
- Ensure the device is mounted on a heatsink or a surface that can effectively dissipate heat.
- Use thermal paste between the device and the heatsink to improve thermal conductivity.
Electrical Connections:
- Connect the anode and cathode terminals correctly to avoid reverse biasing the diode.
- Ensure all connections are secure and free from shorts or loose contacts.
Thermal Management:
- Monitor the junction temperature (TJ) to ensure it does not exceed 150°C.
- If operating at high currents, consider using forced air cooling or a larger heatsink.
Surge Handling:
- The diode can handle surge currents up to 400A for short durations (8.3/400μs). Ensure that any surge conditions are within these limits to avoid damage.
Storage:
- Store the diode in a dry, cool place away from direct sunlight and extreme temperatures.
- Handle with care to avoid mechanical damage.
Testing:
- Before installing the diode in a circuit, test its forward and reverse characteristics using a multimeter or a dedicated diode tester.
- Verify that the forward voltage drop (VF) and reverse leakage current are within the specified limits.
Safety:
- Always follow safety guidelines when handling high-voltage components.
- Use appropriate personal protective equipment (PPE) such as gloves and safety glasses.
Inquiry - MBRF20U60CTA