Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Supply Voltage | VDD | 4.5 | 5.0 | 5.5 | V | Operating supply voltage |
Standby Current | ISB | - | 10 | - | μA | Current in standby mode |
Operating Current | IOP | 100 | 200 | 300 | μA | Current during operation |
Input Voltage Range | VIN | 0 | - | 5.5 | V | Range of input voltages |
Output Voltage Range | VOUT | 0 | - | 5.5 | V | Range of output voltages |
Output Current | IOUT | - | 50 | - | mA | Maximum output current |
Temperature Range | Toper | -40 | - | 85 | °C | Operating temperature range |
Storage Temperature | Tstg | -65 | - | 150 | °C | Storage temperature range |
Thermal Resistance (θJA) | θJA | - | 150 | - | °C/W | Junction to ambient thermal resistance |
ESD Rating | ESD | - | - | 2000 | V | Electrostatic discharge rating |
Instructions for Using the SED9420CAA
Power Supply:
- Ensure the supply voltage (VDD) is within the specified range of 4.5V to 5.5V.
- Connect the power supply to the VDD pin and ground to the GND pin.
Standby Mode:
- To enter standby mode, set the appropriate control signal to low.
- The device will draw minimal current (ISB) in this mode.
Operating Mode:
- Set the control signals to high to activate the device.
- Monitor the operating current (IOP) to ensure it remains within the typical range of 100μA to 300μA.
Input and Output:
- Apply the input voltage (VIN) within the range of 0V to 5.5V.
- The output voltage (VOUT) will be regulated within the same range.
- Ensure the output current (IOUT) does not exceed 50mA.
Temperature Management:
- Operate the device within the temperature range of -40°C to 85°C.
- Store the device in an environment with temperatures between -65°C and 150°C.
Thermal Considerations:
- Use a heatsink or other cooling methods if the device is expected to dissipate significant power.
- The thermal resistance (θJA) is 150°C/W, which can help in thermal design calculations.
Electrostatic Discharge (ESD) Protection:
- Handle the device with proper ESD precautions to avoid damage.
- The device has an ESD rating of 2000V, but it is still sensitive to static electricity.
Mounting and Handling:
- Follow standard surface mount technology (SMT) procedures for mounting the device on a PCB.
- Avoid applying excessive mechanical stress to the pins or body of the device.
By following these parameters and instructions, you can ensure reliable and efficient operation of the SED9420CAA.