IRS2453D SOP

Specifications

SKU: 9755833

BUY IRS2453D SOP https://www.utsource.net/itm/p/9755833.html

Parameter Symbol Test Conditions Min Typical Max Unit
Supply Voltage VCC - 10 - 60 V
Operating Temperature TOP - -40 - 125 °C
Storage Temperature TSTG - -65 - 150 °C
Maximum Output Current IOUT(max) VCC = 15V, TA = 25°C - 200 - mA
Maximum Input Current IIN(max) VCC = 15V, TA = 25°C - 100 - μA
Propagation Delay Time (High to Low) tdHL VCC = 15V, TA = 25°C - 75 - ns
Propagation Delay Time (Low to High) tdLH VCC = 15V, TA = 25°C - 75 - ns
Minimum Pulse Width tPW(min) VCC = 15V, TA = 25°C - 100 - ns
Maximum Duty Cycle Dmax VCC = 15V, TA = 25°C - 99 - %

Instructions for Using IRS2453D SOP:

  1. Supply Voltage (VCC):

    • Ensure the supply voltage is within the range of 10V to 60V to avoid damage to the device.
  2. Operating Temperature (TOP):

    • The device is designed to operate within a temperature range of -40°C to 125°C. Avoid exceeding these limits to prevent performance degradation or failure.
  3. Storage Temperature (TSTG):

    • Store the device in an environment with temperatures ranging from -65°C to 150°C to ensure long-term reliability.
  4. Maximum Output Current (IOUT(max)):

    • The maximum output current is 200mA at a supply voltage of 15V and ambient temperature of 25°C. Do not exceed this limit to avoid overheating and potential damage.
  5. Maximum Input Current (IIN(max)):

    • The maximum input current is 100μA at a supply voltage of 15V and ambient temperature of 25°C. Exceeding this value can lead to improper operation.
  6. Propagation Delay Time:

    • The propagation delay time from high to low (tdHL) and low to high (tdLH) is typically 75ns at a supply voltage of 15V and ambient temperature of 25°C. This is crucial for timing-sensitive applications.
  7. Minimum Pulse Width (tPW(min)):

    • The minimum pulse width is 100ns at a supply voltage of 15V and ambient temperature of 25°C. Ensure that the pulse width is not less than this value to maintain proper functionality.
  8. Maximum Duty Cycle (Dmax):

    • The maximum duty cycle is 99% at a supply voltage of 15V and ambient temperature of 25°C. Higher duty cycles can lead to overheating and reduced efficiency.

Additional Notes:

  • Always refer to the datasheet for the most up-to-date and detailed information.
  • Proper heat sinking and cooling mechanisms should be implemented if operating at high currents or temperatures.
  • Ensure all connections are secure and free from shorts to prevent damage to the device and other components in the circuit.
(For reference only)