Share:


TL074CN TL074

Specifications

SKU: 9767607

BUY TL074CN TL074 https://www.utsource.net/itm/p/9767607.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage Range VCC - ±5 ±15 ±18 V
Quiescent Supply Current (Each Amplifier) ICC VCC = ±15V - 1.3 - mA
Input Offset Voltage VIO - - 2 10 mV
Input Bias Current IB - - 50 150 nA
Input Offset Current IIO - - 10 30 nA
Input Voltage Noise Density en f = 10 kHz - 18 - nV/√Hz
Large Signal Voltage Gain AV VCC = ±15V, RL = 2kΩ - 4000 - V/mV
Slew Rate SR - - 13 - V/μs
Output Short-Circuit Duration tSC - - Indefinite - s
Operating Temperature Range TA - -40 85 125 °C
Storage Temperature Range TSTG - -65 150 - °C

Instructions for Using TL074CN TL074:

  1. Power Supply:

    • Ensure the supply voltage is within the specified range (±5V to ±18V).
    • Use decoupling capacitors (e.g., 0.1 μF and 10 μF) close to the power pins to minimize noise and improve stability.
  2. Input Signals:

    • Keep input signals within the common-mode input voltage range, which is typically from 3V below the negative supply to 3V below the positive supply.
    • Avoid exceeding the maximum differential input voltage (±30V).
  3. Output Load:

    • The output can drive loads down to 600 Ω. For lower impedance loads, consider using a buffer stage.
    • Ensure the output voltage swing does not exceed the power supply rails by more than 1.5V.
  4. Biasing:

    • Use appropriate biasing techniques to ensure the op-amp operates in the linear region.
    • For single-supply applications, use a voltage divider to create a virtual ground reference.
  5. Stability:

    • Use feedback resistors and capacitors to maintain stability, especially at high frequencies.
    • Consider adding a compensation capacitor if the circuit exhibits oscillations or instability.
  6. Temperature Considerations:

    • Operate the device within the specified temperature range (-40°C to 85°C for commercial grade, -40°C to 125°C for extended grade).
    • Store the device within the storage temperature range (-65°C to 150°C).
  7. Handling:

    • Handle the device with care to avoid damage from electrostatic discharge (ESD).
    • Follow proper soldering techniques to prevent thermal stress on the device.
  8. Testing:

    • Before finalizing the design, test the circuit under various conditions to ensure reliable operation.
    • Use a multimeter and oscilloscope to verify the correct operation of the op-amp.

By following these guidelines, you can ensure optimal performance and reliability of the TL074CN TL074 operational amplifier in your circuits.

(For reference only)

 Inquiry - TL074CN TL074