Specifications
SKU: 9767607
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage Range | VCC | - | ±5 | ±15 | ±18 | V |
Quiescent Supply Current (Each Amplifier) | ICC | VCC = ±15V | - | 1.3 | - | mA |
Input Offset Voltage | VIO | - | - | 2 | 10 | mV |
Input Bias Current | IB | - | - | 50 | 150 | nA |
Input Offset Current | IIO | - | - | 10 | 30 | nA |
Input Voltage Noise Density | en | f = 10 kHz | - | 18 | - | nV/√Hz |
Large Signal Voltage Gain | AV | VCC = ±15V, RL = 2kΩ | - | 4000 | - | V/mV |
Slew Rate | SR | - | - | 13 | - | V/μs |
Output Short-Circuit Duration | tSC | - | - | Indefinite | - | s |
Operating Temperature Range | TA | - | -40 | 85 | 125 | °C |
Storage Temperature Range | TSTG | - | -65 | 150 | - | °C |
Instructions for Using TL074CN TL074:
Power Supply:
- Ensure the supply voltage is within the specified range (±5V to ±18V).
- Use decoupling capacitors (e.g., 0.1 μF and 10 μF) close to the power pins to minimize noise and improve stability.
Input Signals:
- Keep input signals within the common-mode input voltage range, which is typically from 3V below the negative supply to 3V below the positive supply.
- Avoid exceeding the maximum differential input voltage (±30V).
Output Load:
- The output can drive loads down to 600 Ω. For lower impedance loads, consider using a buffer stage.
- Ensure the output voltage swing does not exceed the power supply rails by more than 1.5V.
Biasing:
- Use appropriate biasing techniques to ensure the op-amp operates in the linear region.
- For single-supply applications, use a voltage divider to create a virtual ground reference.
Stability:
- Use feedback resistors and capacitors to maintain stability, especially at high frequencies.
- Consider adding a compensation capacitor if the circuit exhibits oscillations or instability.
Temperature Considerations:
- Operate the device within the specified temperature range (-40°C to 85°C for commercial grade, -40°C to 125°C for extended grade).
- Store the device within the storage temperature range (-65°C to 150°C).
Handling:
- Handle the device with care to avoid damage from electrostatic discharge (ESD).
- Follow proper soldering techniques to prevent thermal stress on the device.
Testing:
- Before finalizing the design, test the circuit under various conditions to ensure reliable operation.
- Use a multimeter and oscilloscope to verify the correct operation of the op-amp.
By following these guidelines, you can ensure optimal performance and reliability of the TL074CN TL074 operational amplifier in your circuits.
(For reference only)Inquiry - TL074CN TL074