Parameter Symbol Min Typ Max Unit Condition
Forward Voltage VF - 1.2 1.5 V IF = 20 mA
Reverse Breakdown Voltage VBR 5 - 7 V IR = 10 μA
Continuous Forward Current IF - - 30 mA Ta = 25°C
Peak Forward Current IF(surge) - - 100 mA t = 10 ms, Repetition Rate = 100/s
Storage Temperature TSTG -40 - 85 °C -
Operating Temperature TA -40 - 85 °C -
Output Leakage Current IOL - 1 5 μA VO = 0 V, TA = 25°C
Output Turn-ON Time ton - 2 5 μs VI = 5 V, RL = 1 kΩ, CL = 100 pF
Output Turn-OFF Time toff - 2 5 μs VI = 0 V, RL = 1 kΩ, CL = 100 pF

Instructions for Use:

  1. Mounting and Handling:

    • Handle the TLP261J(F) with care to avoid mechanical stress.
    • Ensure proper grounding to prevent electrostatic discharge (ESD).
  2. Power Supply:

    • Apply the forward current (IF) within the specified limits to avoid overheating and damage.
    • Ensure the reverse voltage (VBR) does not exceed the maximum rating.
  3. Temperature Considerations:

    • Operate the device within the specified temperature range (TA and TSTG) to ensure reliable performance.
    • Provide adequate heat dissipation if operating at high temperatures or high currents.
  4. Signal Integrity:

    • Use appropriate decoupling capacitors to filter out noise and ensure stable operation.
    • Keep signal traces short to minimize inductance and capacitance effects.
  5. Storage:

    • Store the device in a dry, cool place to prevent moisture damage.
    • Follow ESD handling guidelines during storage and transportation.
  6. Testing:

    • Use a constant current source to test the forward voltage (VF).
    • Measure the output leakage current (IOL) under no-load conditions to verify proper operation.
  7. Safety:

    • Ensure all connections are secure and insulated to prevent short circuits.
    • Follow all relevant safety standards and regulations when designing and testing circuits.