Specifications
SKU: 9896790
IC TXRX ISOL HALF 1/1 16SOIC
Parameter | Description | Min | Typ | Max | Unit |
---|---|---|---|---|---|
Supply Voltage (Vcc) | Operating supply voltage range | 2.7 | - | 5.25 | V |
Data Rate | Maximum data rate | - | - | 250 | kbps |
Driver Output Voltage (Vod) | Differential output voltage at 56 Ω load | 1.5 | - | 2.5 | V |
Receiver Input Voltage Range (Vin) | Differential input voltage range | -7 | - | 12 | V |
Input Current (Iin) | Maximum input current per line | - | - | ±100 | μA |
Output Short-Circuit Duration | Continuous output short-circuit protection | - | - | Continuous | - |
ESD Protection | Human body model (HBM) | - | - | 8 | kV |
Operating Temperature Range | Ambient temperature range for operation | -40 | - | 85 | °C |
Storage Temperature Range | Temperature range for storage | -65 | - | 150 | °C |
Power Consumption | Typical power consumption at 3.3V supply | - | 0.8 | - | mA |
Instructions for Using ADM3050EBRWZ
Power Supply:
- Connect the Vcc pin to a stable power supply within the range of 2.7V to 5.25V.
- Ensure the ground (GND) pin is connected to the system ground.
Data Lines:
- Connect the differential data lines (TXD+ and TXD-, RXD+ and RXD-) to the corresponding lines of the communication interface.
- Use 56 Ω termination resistors on the differential lines to match the characteristic impedance of the transmission medium.
Configuration:
- The ADM3050E is designed to operate in a half-duplex mode. The direction of data flow is controlled by the DE (Driver Enable) and RE (Receiver Enable) pins.
- Set DE high to enable the driver (transmit mode).
- Set RE low to enable the receiver (receive mode).
- To disable both the driver and receiver, set DE low and RE high.
ESD Protection:
- Handle the device with care to avoid electrostatic discharge (ESD).
- Use appropriate ESD protection measures during handling and installation.
Temperature Considerations:
- Ensure that the operating temperature remains within the specified range of -40°C to 85°C.
- Store the device in a temperature-controlled environment between -65°C and 150°C.
Short-Circuit Protection:
- The device has built-in continuous output short-circuit protection. However, avoid prolonged short circuits to prevent potential damage.
Power Consumption:
- The typical power consumption is 0.8 mA at a 3.3V supply. Ensure the power supply can handle this current requirement.
Signal Integrity:
- Use proper PCB layout techniques to minimize noise and ensure signal integrity.
- Keep the traces as short as possible and use ground planes to reduce interference.
Testing:
- After installation, test the device to ensure it is functioning correctly.
- Verify the data transmission and reception using a known good communication protocol and test equipment.
By following these instructions, you can ensure reliable operation of the ADM3050EBRWZ in your application.
(For reference only)Inquiry - ADM3050EBRWZ