Specifications
SKU: 10069244
Parameter | Symbol | Min | Typ | Max | Unit | Condition |
---|---|---|---|---|---|---|
Forward Voltage Drop (VF) | VFS | - | 1.8 | 2.2 | V | IF = 400 A, Tj = 25°C |
Reverse Recovery Time (trr) | trr | - | 70 | 90 | ns | IRR = 100 A, di/dt = 100 A/μs, Tj = 25°C |
Maximum Junction Temperature | Tjmax | - | - | 150 | °C | - |
Storage Temperature Range | Tstg | -55 | - | 150 | °C | - |
Continuous Forward Current (TC = 25°C) | IF(25°C) | - | 400 | - | A | - |
Continuous Forward Current (TC = 100°C) | IF(100°C) | - | 320 | - | A | - |
Peak Forward Surge Current (10 ms, single pulse) | IFsm | - | 1200 | - | A | - |
Reverse Repetitive Peak Voltage | VRRM | - | - | 1200 | V | - |
Reverse Leakage Current (Tj = 25°C) | IR(25°C) | - | 10 | - | mA | VRRM = 1200 V |
Reverse Leakage Current (Tj = 150°C) | IR(150°C) | - | 50 | - | mA | VRRM = 1200 V |
Thermal Resistance (Junction to Case) | RthJC | - | 0.03 | - | K/W | - |
Thermal Resistance (Junction to Ambient) | RthJA | - | 0.6 | - | K/W | - |
Instructions for Use:
Mounting and Handling:
- Ensure that the device is handled with care to avoid mechanical damage.
- Use appropriate mounting techniques to ensure good thermal contact between the device and the heatsink.
Electrical Connections:
- Connect the device according to the specified electrical parameters.
- Ensure that the connections are secure and free from any loose contacts or short circuits.
Thermal Management:
- Monitor the junction temperature to ensure it does not exceed the maximum rated value of 150°C.
- Use a heatsink with adequate thermal resistance to dissipate the heat generated by the device.
Surge Current Handling:
- The device can handle peak forward surge currents up to 1200 A for a single 10 ms pulse. Ensure that the surge current does not exceed this limit to prevent damage.
Reverse Voltage Protection:
- The reverse repetitive peak voltage is 1200 V. Ensure that the reverse voltage applied to the device does not exceed this value to avoid breakdown.
Storage Conditions:
- Store the device in a dry and cool environment within the temperature range of -55°C to 150°C to maintain its performance and reliability.
Testing and Verification:
- Perform regular testing and verification to ensure that the device is operating within its specified parameters.
- Use appropriate test equipment and methods to avoid damaging the device during testing.
Inquiry - BSM400GA120DLC