Parameter Symbol Min Typ Max Unit Condition
Forward Voltage Drop (VF) VFS - 1.8 2.2 V IF = 400 A, Tj = 25°C
Reverse Recovery Time (trr) trr - 70 90 ns IRR = 100 A, di/dt = 100 A/μs, Tj = 25°C
Maximum Junction Temperature Tjmax - - 150 °C -
Storage Temperature Range Tstg -55 - 150 °C -
Continuous Forward Current (TC = 25°C) IF(25°C) - 400 - A -
Continuous Forward Current (TC = 100°C) IF(100°C) - 320 - A -
Peak Forward Surge Current (10 ms, single pulse) IFsm - 1200 - A -
Reverse Repetitive Peak Voltage VRRM - - 1200 V -
Reverse Leakage Current (Tj = 25°C) IR(25°C) - 10 - mA VRRM = 1200 V
Reverse Leakage Current (Tj = 150°C) IR(150°C) - 50 - mA VRRM = 1200 V
Thermal Resistance (Junction to Case) RthJC - 0.03 - K/W -
Thermal Resistance (Junction to Ambient) RthJA - 0.6 - K/W -

Instructions for Use:

  1. Mounting and Handling:

    • Ensure that the device is handled with care to avoid mechanical damage.
    • Use appropriate mounting techniques to ensure good thermal contact between the device and the heatsink.
  2. Electrical Connections:

    • Connect the device according to the specified electrical parameters.
    • Ensure that the connections are secure and free from any loose contacts or short circuits.
  3. Thermal Management:

    • Monitor the junction temperature to ensure it does not exceed the maximum rated value of 150°C.
    • Use a heatsink with adequate thermal resistance to dissipate the heat generated by the device.
  4. Surge Current Handling:

    • The device can handle peak forward surge currents up to 1200 A for a single 10 ms pulse. Ensure that the surge current does not exceed this limit to prevent damage.
  5. Reverse Voltage Protection:

    • The reverse repetitive peak voltage is 1200 V. Ensure that the reverse voltage applied to the device does not exceed this value to avoid breakdown.
  6. Storage Conditions:

    • Store the device in a dry and cool environment within the temperature range of -55°C to 150°C to maintain its performance and reliability.
  7. Testing and Verification:

    • Perform regular testing and verification to ensure that the device is operating within its specified parameters.
    • Use appropriate test equipment and methods to avoid damaging the device during testing.
(For reference only)

 Inquiry - BSM400GA120DLC