Share:


6DI100A-060

Specifications

SKU: 10093044

BUY 6DI100A-060 https://www.utsource.net/itm/p/10093044.html

Parameter Description Value
Part Number Full part number 6DI100A-060
Type Component type Diode
Technology Diode technology Silicon
Maximum Reverse Voltage (V_RRMS) Maximum reverse voltage 600 V
Maximum Average Rectified Current (I_F(AV)) Continuous forward current at T_A = 25°C 100 A
Peak Repetitive Reverse Voltage (V_RRM) Peak repetitive reverse voltage 600 V
Peak Forward Surge Current (I_FSM) Non-repetitive peak forward surge current (8.3 ms single half sine-wave) 800 A
Forward Voltage Drop (V_F) Forward voltage drop at I_F = 100 A, T_J = 25°C 1.1 V
Reverse Recovery Time (t_rr) Reverse recovery time at I_F = 100 A, I_RM = 10 A, T_J = 25°C 150 ns
Thermal Resistance (R_th(j-c)) Junction to case thermal resistance 0.15 K/W
Operating Temperature Range (T_J) Junction temperature range -55°C to +175°C
Storage Temperature Range (T_STG) Storage temperature range -55°C to +175°C
Package Package type TO-247-2L

Instructions for Use:

  1. Mounting:

    • Ensure that the diode is mounted on a heatsink with adequate thermal management to maintain the junction temperature within the specified range.
    • Use a thermal compound to enhance heat transfer between the diode and the heatsink.
  2. Electrical Connections:

    • Connect the anode and cathode terminals correctly to avoid reverse breakdown.
    • Ensure that the connections are secure and free from mechanical stress.
  3. Surge Handling:

    • The diode can handle non-repetitive surge currents up to 800 A. Ensure that any surge conditions are within this limit to prevent damage.
  4. Thermal Management:

    • Monitor the junction temperature to ensure it does not exceed 175°C. Use appropriate cooling methods such as forced air or liquid cooling if necessary.
  5. Storage:

    • Store the diode in a dry, cool place within the specified storage temperature range (-55°C to +175°C).
  6. Handling:

    • Handle the diode with care to avoid mechanical damage. Use anti-static precautions to prevent electrostatic discharge (ESD) damage.
  7. Testing:

    • Before installing the diode in a circuit, perform a visual inspection and verify the electrical parameters using a multimeter or other testing equipment.
  8. Compliance:

    • Ensure that the diode meets all relevant safety and regulatory standards for your application.
(For reference only)