Specifications
SKU: 10124237
Parameter | Description | Value |
---|---|---|
Part Number | The specific identifier for this component | A1040C |
Type | Type of component | Hall Effect Sensor |
Supply Voltage (Vcc) | Operating voltage range for the device | 4.5 V to 24 V |
Quiescent Output Voltage (VQ) at No Field | Output voltage when no magnetic field is present | 0.5 V to 4.5 V |
Magnetic Sensitivity (BOP) | Magnetic field strength required to switch the output from high to low | -25 Gauss to -65 Gauss |
Release Point (BRP) | Magnetic field strength required to switch the output from low to high | +25 Gauss to +65 Gauss |
Output Current (IO) at Vcc = 24 V | Maximum output current the device can sink | 20 mA |
Operating Temperature Range (TA) | Temperature range in which the device can operate reliably | -40°C to 150°C |
Storage Temperature Range (TSTG) | Temperature range in which the device can be stored without damage | -40°C to 150°C |
Package Type | Physical package of the component | SOT-23 |
Lead Pitch | Distance between the centers of two adjacent leads | 2.54 mm |
Instructions for Use:
Power Supply:
- Connect the Vcc pin to a power supply within the specified range (4.5 V to 24 V).
- Connect the GND pin to the ground of the power supply.
Output Connection:
- Connect the OUT pin to the input of your control circuit.
- Ensure that the load connected to the output does not exceed the maximum output current (20 mA).
Magnetic Field Application:
- Place the sensor in a position where it will be exposed to the magnetic field you want to detect.
- The sensor will switch its output state based on the magnetic field strength. It will switch to a low state when the magnetic field exceeds the BOP threshold and switch back to a high state when the field drops below the BRP threshold.
Temperature Considerations:
- Ensure that the operating temperature remains within the specified range (-40°C to 150°C) to avoid damage or unreliable operation.
- Store the sensor in an environment within the storage temperature range (-40°C to 150°C).
Handling Precautions:
- Handle the sensor with care to avoid mechanical stress, which could affect its performance.
- Avoid exposing the sensor to excessive humidity or corrosive environments.
Testing:
- Before integrating the sensor into a larger system, test it individually to ensure it meets the required specifications.
- Use a known magnetic field source to verify the BOP and BRP thresholds.
Mounting:
- Mount the sensor using appropriate methods to ensure it is securely fastened and aligned with the magnetic field source.
- Follow the recommended soldering and reflow profiles to avoid thermal damage during assembly.