Specifications
SKU: 11200959
IC MUX 2 X 4:1 4 OHM 16SOIC
Parameter | Symbol | Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VCC | - | 2.0 | - | 6.0 | V |
Input Voltage (High) | VIH | IIH = 1 μA | 3.15 | - | VCC | V |
Input Voltage (Low) | VIL | IIL = -1 μA | 0 | - | 1.35 | V |
Output Voltage (High) | VOH | IOH = -1 mA, VCC = 5 V | 3.5 | - | VCC | V |
Output Voltage (Low) | VOL | IOL = 1 mA, VCC = 5 V | 0 | - | 0.25 | V |
Input Leakage Current | IIL | VI = 0 V to VCC | -1 | - | 1 | μA |
Output Leakage Current | IOL | VO = 0 V to VCC | -1 | - | 1 | μA |
Channel-to-Channel Isolation | - | f = 1 MHz, VCC = 5 V | - | - | 100 | dB |
Insertion Loss | - | f = 1 MHz, VCC = 5 V | - | - | 0.5 | dB |
Switching Time (tpd) | - | VCC = 5 V, f = 1 MHz | - | 10 | 50 | ns |
Operating Temperature Range | TA | - | -40 | - | 85 | °C |
Storage Temperature Range | TSTG | - | -65 | - | 150 | °C |
Instructions for Using 74HC4052D:
Power Supply:
- Connect the VCC pin to the positive supply voltage (2.0 V to 6.0 V).
- Connect the GND pin to the ground.
Input Control:
- Use the S0, S1, and EN pins to control the selection of the multiplexer/demultiplexer channels.
- S0 and S1 determine which channel is selected (00 to 11).
- EN (Enable) pin must be low to enable the device; high to disable.
Signal Routing:
- The device can route signals from any of the 4 input channels to the common output or vice versa.
- Ensure that the input signals do not exceed the supply voltage range.
Channel Selection:
- For example, to select channel 0:
- Set S0 to 0 and S1 to 0.
- To select channel 1:
- Set S0 to 1 and S1 to 0.
- Continue this pattern for other channels.
- For example, to select channel 0:
Signal Integrity:
- Keep signal lines as short as possible to minimize noise and crosstalk.
- Use appropriate decoupling capacitors (e.g., 0.1 μF) close to the VCC and GND pins to stabilize the power supply.
Temperature Considerations:
- Ensure the operating temperature is within the specified range (-40°C to 85°C).
- Avoid exposing the device to temperatures outside the storage range (-65°C to 150°C).
Handling Precautions:
- Handle the device with care to avoid static damage.
- Use proper ESD protection when handling the device.
Testing and Verification:
- After assembly, verify the correct operation of the device by testing the signal routing and control logic.
- Use an oscilloscope or multimeter to check the signal levels at the input and output pins.
Inquiry - 74HC4052D