Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Input Forward Voltage | VF | - | 1.2 | 1.6 | V | IF = 10 mA, TA = 25°C |
Input Peak Forward Current | IF(peak) | - | - | 100 | mA | t < 1 ms, IF(AV) = 10 mA |
Input Average Forward Current | IF(AV) | 5 | - | 20 | mA | TA = 25°C |
Output Collector-Emitter Saturation Voltage | VCE(sat) | - | 0.3 | 0.5 | V | IC = 5 mA, TA = 25°C |
Output Collector Current | IC | - | - | 5 | mA | VCE = 5 V, TA = 25°C |
Output Leakage Current | ICEO | - | 0.1 | 1 | μA | VCE = 5 V, TA = 25°C |
Isolation Voltage | VIORM | 1500 | - | - | V | 1 minute, 50/60 Hz |
Operating Temperature Range | TOPR | -40 | - | 85 | °C | - |
Storage Temperature Range | TSTG | -55 | - | 125 | °C | - |
Instructions for Use:
Power Supply:
- Ensure the input voltage (VF) is within the specified range to avoid damage to the device.
- The input current (IF) should not exceed the maximum average or peak values.
Output Circuit:
- The output collector-emitter voltage (VCE) should be kept below the maximum rating to prevent breakdown.
- The output collector current (IC) should not exceed the maximum value to ensure reliable operation.
Thermal Management:
- Operate the device within the specified temperature range (TOPR) to ensure proper functionality.
- For extended operation at high temperatures, consider heat sinking or other cooling methods.
Isolation:
- The device provides isolation up to the specified isolation voltage (VIORM). Ensure that the isolation requirements of your application are met.
Handling:
- Handle the device with care to avoid static discharge, which can damage sensitive components.
- Follow standard ESD (Electrostatic Discharge) precautions during handling and installation.
Storage:
- Store the device in a dry, cool place within the specified storage temperature range (TSTG).
Testing:
- Before integrating the device into a circuit, test it under controlled conditions to verify its performance parameters.
By following these guidelines, you can ensure the reliable and efficient operation of the TLP570 optocoupler.