Share:


IS42S32400E-7TLI

Specifications

SKU: 11212504

BUY IS42S32400E-7TLI https://www.utsource.net/itm/p/11212504.html
IC DRAM 128M PARALLEL 86TSOP II
Parameter Name Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating 2.5 - 3.6 V
Standby Current (All Banks) ICC VCC = 3.3V, No Refresh - 20 - μA
Active Current (Single Bank) ICC VCC = 3.3V, 133 MHz - 180 - mA
Access Time tAA VCC = 3.3V, CL = 3 - 7 - ns
Row Address Strobe to Column Address Strobe Delay tRCD VCC = 3.3V, CL = 3 - 7 - ns
Row Precharge Time tRP VCC = 3.3V, CL = 3 - 7 - ns
Row Active to Row Active Delay tRRD VCC = 3.3V, CL = 3 - 3 - ns
Write Recovery Time tWR VCC = 3.3V, CL = 3 - 3 - ns
Refresh Cycle Time tRC VCC = 3.3V, CL = 3 - 64 - ns
Data Output Enable Setup Time tDS VCC = 3.3V, CL = 3 - 0.5 - ns
Data Output Enable Hold Time tDH VCC = 3.3V, CL = 3 - 0.5 - ns

Instructions for IS42S32400E-7TLI

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 2.5V to 3.6V.
    • Use a stable power source to avoid fluctuations that could affect performance.
  2. Initialization:

    • Before performing any operations, ensure the device is properly initialized.
    • Set the mode register according to the desired operating parameters (e.g., CAS Latency, Burst Length).
  3. Memory Operations:

    • Read Operation:
      • Apply the appropriate row and column addresses.
      • Ensure the access time (tAA) is respected to avoid data corruption.
    • Write Operation:
      • Apply the write command with the necessary row and column addresses.
      • Ensure the write recovery time (tWR) is respected to prevent data loss.
  4. Refresh:

    • Perform refresh cycles at intervals not exceeding the refresh cycle time (tRC).
    • This is crucial to maintain the integrity of the stored data.
  5. Timing Parameters:

    • Adhere to all specified timing parameters to ensure reliable operation.
    • Pay special attention to setup and hold times for control signals to avoid metastability issues.
  6. Power Management:

    • To reduce power consumption, use the standby mode when the device is not actively being used.
    • Ensure the standby current (ICC) is within acceptable limits to minimize power drain.
  7. Handling:

    • Handle the device with care to avoid electrostatic discharge (ESD) damage.
    • Follow proper ESD protection guidelines during handling and installation.
  8. Testing:

    • After installation, perform thorough testing to verify the functionality and performance of the device.
    • Check for any potential issues such as incorrect addressing or timing violations.
(For reference only)

 Inquiry - IS42S32400E-7TLI