SKU: 11217414
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Drain-Source Voltage | VDS | - | - | 55 | V | |
Gate-Source Voltage | VGS | -15 | - | 20 | V | |
Continuous Drain Current | ID | - | 35 | - | A | TC = 25°C |
Continuous Drain Current | ID | - | 28 | - | A | TC = 75°C |
Pulse Drain Current | ID(p) | - | 110 | - | A | tp = 10 ms, Duty Cycle = 1% |
Power Dissipation | PTOT | - | 160 | - | W | TC = 25°C |
Junction Temperature | TJ | - | - | 150 | °C | |
Storage Temperature Range | TSTG | -55 | - | 150 | °C | |
Thermal Resistance, Junction to Case | RθJC | - | 0.5 | - | °C/W | |
Total Gate Charge | QG | - | 125 | - | nC | |
Input Capacitance | Ciss | - | 2200 | - | pF | VDS = 10 V, f = 1 MHz |
Output Capacitance | Coss | - | 600 | - | pF | VDS = 10 V, f = 1 MHz |
Reverse Transfer Capacitance | Crss | - | 550 | - | pF | VDS = 10 V, f = 1 MHz |
Threshold Gate Voltage | VGS(th) | 1.0 | 1.4 | 2.0 | V | ID = 250 μA, TA = 25°C |
On-State Resistance | RDS(on) | - | 4.5 | - | mΩ | VGS = 10 V, ID = 35 A, TA = 25°C |
Turn-On Delay Time | td(on) | - | 48 | - | ns | VDS = 5 V, ID = 35 A, VGS = 10 V, RG = 2 Ω |
Rise Time | tr | - | 40 | - | ns | VDS = 5 V, ID = 35 A, VGS = 10 V, RG = 2 Ω |
Turn-Off Delay Time | td(off) | - | 22 | - | ns | VDS = 5 V, ID = 35 A, VGS = 0 V, RG = 2 Ω |
Fall Time | tf | - | 20 | - | ns | VDS = 5 V, ID = 35 A, VGS = 0 V, RG = 2 Ω |
Instructions for Use:
Handling and Storage:
- Store in a dry, cool place.
- Handle with care to avoid damage to the leads and the body of the device.
Mounting:
- Ensure proper heat sinking to manage thermal resistance.
- Use appropriate mounting hardware to secure the device.
Electrical Connections:
- Connect the drain (D), source (S), and gate (G) terminals correctly.
- Use a gate resistor (RG) to control switching speed and reduce electromagnetic interference (EMI).
Operating Conditions:
- Do not exceed the maximum ratings for VDS, VGS, ID, and power dissipation.
- Operate within the specified temperature range to ensure reliable performance.
Testing:
- Test the device under controlled conditions to verify its performance.
- Use a suitable test setup to measure parameters like RDS(on) and switching times.
Safety Precautions:
- Always use appropriate safety equipment when handling high voltages and currents.
- Follow all relevant electrical and mechanical safety guidelines.
Troubleshooting:
- If the device fails to operate as expected, check for proper connections, correct biasing, and any signs of overheating or physical damage.