Share:


IRL1404

Specifications

SKU: 11217414

BUY IRL1404 https://www.utsource.net/itm/p/11217414.html

Parameter Symbol Min Typ Max Unit Conditions
Drain-Source Voltage VDS - - 55 V
Gate-Source Voltage VGS -15 - 20 V
Continuous Drain Current ID - 35 - A TC = 25°C
Continuous Drain Current ID - 28 - A TC = 75°C
Pulse Drain Current ID(p) - 110 - A tp = 10 ms, Duty Cycle = 1%
Power Dissipation PTOT - 160 - W TC = 25°C
Junction Temperature TJ - - 150 °C
Storage Temperature Range TSTG -55 - 150 °C
Thermal Resistance, Junction to Case RθJC - 0.5 - °C/W
Total Gate Charge QG - 125 - nC
Input Capacitance Ciss - 2200 - pF VDS = 10 V, f = 1 MHz
Output Capacitance Coss - 600 - pF VDS = 10 V, f = 1 MHz
Reverse Transfer Capacitance Crss - 550 - pF VDS = 10 V, f = 1 MHz
Threshold Gate Voltage VGS(th) 1.0 1.4 2.0 V ID = 250 μA, TA = 25°C
On-State Resistance RDS(on) - 4.5 - VGS = 10 V, ID = 35 A, TA = 25°C
Turn-On Delay Time td(on) - 48 - ns VDS = 5 V, ID = 35 A, VGS = 10 V, RG = 2 Ω
Rise Time tr - 40 - ns VDS = 5 V, ID = 35 A, VGS = 10 V, RG = 2 Ω
Turn-Off Delay Time td(off) - 22 - ns VDS = 5 V, ID = 35 A, VGS = 0 V, RG = 2 Ω
Fall Time tf - 20 - ns VDS = 5 V, ID = 35 A, VGS = 0 V, RG = 2 Ω

Instructions for Use:

  1. Handling and Storage:

    • Store in a dry, cool place.
    • Handle with care to avoid damage to the leads and the body of the device.
  2. Mounting:

    • Ensure proper heat sinking to manage thermal resistance.
    • Use appropriate mounting hardware to secure the device.
  3. Electrical Connections:

    • Connect the drain (D), source (S), and gate (G) terminals correctly.
    • Use a gate resistor (RG) to control switching speed and reduce electromagnetic interference (EMI).
  4. Operating Conditions:

    • Do not exceed the maximum ratings for VDS, VGS, ID, and power dissipation.
    • Operate within the specified temperature range to ensure reliable performance.
  5. Testing:

    • Test the device under controlled conditions to verify its performance.
    • Use a suitable test setup to measure parameters like RDS(on) and switching times.
  6. Safety Precautions:

    • Always use appropriate safety equipment when handling high voltages and currents.
    • Follow all relevant electrical and mechanical safety guidelines.
  7. Troubleshooting:

    • If the device fails to operate as expected, check for proper connections, correct biasing, and any signs of overheating or physical damage.
(For reference only)