Share:


BSP254A

Specifications

SKU: 11218784

BUY BSP254A https://www.utsource.net/itm/p/11218784.html

Parameter Symbol Min Typ Max Unit
Drain-Source Voltage VDS -60 - -100 V
Gate-Source Voltage VGS -30 - 15 V
Continuous Drain Current ID - 4 4.8 A
Pulse Drain Current IDpeak - 8 8 A
Power Dissipation PTOT - - 100 W
Junction Temperature TJ -55 - 175 °C
Storage Temperature TSTG -55 - 150 °C
Thermal Resistance, Junction to Case RθJC - 0.75 - K/W

Instructions for Use:

  1. Voltage Ratings:

    • Ensure that the drain-source voltage (VDS) does not exceed -100V or go below -60V.
    • The gate-source voltage (VGS) should be within -30V to +15V.
  2. Current Ratings:

    • The continuous drain current (ID) should not exceed 4.8A.
    • For pulse applications, the peak drain current (IDpeak) can be up to 8A.
  3. Power Dissipation:

    • The maximum power dissipation (PTOT) is 100W. Ensure adequate heat sinking to manage thermal conditions.
  4. Temperature Considerations:

    • The junction temperature (TJ) must remain between -55°C and 175°C.
    • The storage temperature (TSTG) range is from -55°C to 150°C.
  5. Thermal Management:

    • The thermal resistance from the junction to the case (RθJC) is 0.75 K/W. Use appropriate heat sinks or cooling methods to maintain the junction temperature within safe limits.
  6. Handling and Storage:

    • Handle the device with care to avoid damage to the leads and body.
    • Store the device in a dry, cool environment within the specified storage temperature range.
  7. Mounting:

    • Follow the recommended mounting procedures to ensure proper electrical and thermal connections.
    • Use a torque wrench to apply the correct torque to the mounting screws to avoid over-tightening or under-tightening.
  8. Electrostatic Discharge (ESD) Protection:

    • Use ESD protection measures when handling the device to prevent damage from static electricity.
  9. Testing:

    • Perform initial testing at low voltages and currents to verify proper operation before applying full ratings.
  10. Compliance:

    • Ensure that the device is used in compliance with all relevant safety and regulatory standards.
(For reference only)