Share:


PCF8563T/5

Specifications

SKU: 11220352

BUY PCF8563T/5 https://www.utsource.net/itm/p/11220352.html

Parameter Symbol Min Typ Max Unit Description
Supply Voltage VDD 2.0 3.0 5.5 V Operating supply voltage range
Standby Current IDD(STBY) - 700 - nA Current consumption in standby mode (VDD = 3.0V, fOUT off)
Operating Current IDD(OP) - 400 - μA Current consumption during operation (VDD = 3.0V, fOUT on)
Output Frequency fOUT 32.768 - 32.768 kHz Oscillator output frequency
Temperature Range TA -40 - 85 °C Operating temperature range
Clock Accuracy Δf/f -20 - +20 ppm Frequency accuracy at 25°C
Timekeeping Resolution - - - - 1s Minimum time increment
Alarm Function - - - - Yes Supports alarm functionality
Timer Function - - - - Yes Supports timer functionality
Power-On Reset - - - - Yes Automatic reset on power-on

Instructions for Using the PCF8563T/5

  1. Power Supply:

    • Ensure the supply voltage (VDD) is within the range of 2.0V to 5.5V.
    • Connect the VDD pin to the positive supply and the GND pin to the ground.
  2. Oscillator Configuration:

    • Connect a 32.768 kHz crystal between the X1 and X2 pins for accurate timekeeping.
    • The oscillator can be disabled by setting the appropriate register bit to save power.
  3. I2C Communication:

    • Use the SDA and SCL pins for I2C communication.
    • Set the device address to 0x51 (7-bit address).
  4. Register Access:

    • Read and write to the internal registers to set the time, date, alarms, and timers.
    • Refer to the datasheet for the specific register addresses and their functions.
  5. Time Setting:

    • Write the current time and date to the respective registers (seconds, minutes, hours, day, date, month, year).
    • Use BCD (Binary-Coded Decimal) format for the time and date values.
  6. Alarm and Timer Setup:

    • Configure the alarm and timer settings by writing to the corresponding registers.
    • Enable the alarm or timer by setting the appropriate control bits.
  7. Interrupt Handling:

    • The device can generate interrupts for alarms and timers.
    • Check the status register to determine the cause of the interrupt and clear it as needed.
  8. Power Management:

    • To minimize power consumption, disable the oscillator and other features when not in use.
    • Use the standby mode to reduce current consumption to 700 nA.
  9. Temperature Considerations:

    • The device operates over a temperature range of -40°C to 85°C.
    • Ensure the device is used within this range to maintain accuracy and reliability.
  10. Reset Functionality:

    • The device has an automatic power-on reset feature.
    • After power-on, the device will initialize its registers to default values.
(For reference only)

 Inquiry - PCF8563T/5