Parameter | Symbol | Min | Typ | Max | Unit | Description |
---|---|---|---|---|---|---|
Supply Voltage | Vcc | 4.5 | 5 | 5.5 | V | Operating supply voltage |
Input High Voltage | VIH | 2.0 | - | 5.5 | V | Minimum input high voltage |
Input Low Voltage | VIL | 0 | - | 0.8 | V | Maximum input low voltage |
Output High Voltage | VOH | 2.4 | - | 5.5 | V | Minimum output high voltage |
Output Low Voltage | VOL | 0 | - | 0.4 | V | Maximum output low voltage |
Input Leakage Current | IIH | - | 1 | 20 | μA | Maximum input leakage current (VIH) |
Input Leakage Current | IIL | -20 | -1 | - | μA | Maximum input leakage current (VIL) |
Output Leakage Current | IOH | - | 50 | 100 | μA | Maximum output leakage current (VOH) |
Output Leakage Current | IOL | -100 | -50 | - | μA | Maximum output leakage current (VOL) |
Propagation Delay Time | tpd | 20 | 35 | 60 | ns | Propagation delay time from input to output |
Power Consumption | ICC | 0 | 10 | 30 | μA | Quiescent current at no load |
Operating Temperature | Ta | -40 | - | 85 | °C | Ambient operating temperature range |
Storage Temperature | Tstg | -65 | - | 150 | °C | Storage temperature range |
Instructions for Using GD75188
Supply Voltage:
- Ensure the supply voltage is within the specified range (4.5V to 5.5V). Use a stable power source to avoid voltage fluctuations.
Input Signals:
- For a valid high input, ensure the voltage is at least 2.0V.
- For a valid low input, ensure the voltage does not exceed 0.8V.
- Avoid connecting inputs to voltages outside the VIL and VIH ranges to prevent damage or incorrect operation.
Output Signals:
- The output will be high (at least 2.4V) when the input is high.
- The output will be low (no more than 0.4V) when the input is low.
- Ensure the load connected to the output does not exceed the maximum current ratings (IOH and IOL).
Leakage Current:
- Be aware of the input and output leakage currents to avoid unexpected behavior in sensitive circuits.
Propagation Delay:
- Account for the propagation delay time (20ns to 60ns) when designing timing-sensitive circuits.
Power Consumption:
- The quiescent current (ICC) is typically around 10μA but can vary between 0μA and 30μA. Ensure the power supply can handle this current.
Temperature Considerations:
- Operate the device within the ambient temperature range (-40°C to 85°C) to ensure reliable performance.
- Store the device within the storage temperature range (-65°C to 150°C) to prevent damage.
Handling and Installation:
- Handle the device with care to avoid static discharge, which can damage the internal components.
- Follow proper soldering techniques to ensure good electrical connections and avoid thermal stress.
Testing:
- Test the device under typical operating conditions to verify its functionality before integrating it into a larger system.
By following these guidelines, you can ensure optimal performance and reliability of the GD75188 in your electronic designs.
(For reference only)Inquiry - GD75188