Share:


GD75188

Specifications

SKU: 11223675

BUY GD75188 https://www.utsource.net/itm/p/11223675.html

Parameter Symbol Min Typ Max Unit Description
Supply Voltage Vcc 4.5 5 5.5 V Operating supply voltage
Input High Voltage VIH 2.0 - 5.5 V Minimum input high voltage
Input Low Voltage VIL 0 - 0.8 V Maximum input low voltage
Output High Voltage VOH 2.4 - 5.5 V Minimum output high voltage
Output Low Voltage VOL 0 - 0.4 V Maximum output low voltage
Input Leakage Current IIH - 1 20 μA Maximum input leakage current (VIH)
Input Leakage Current IIL -20 -1 - μA Maximum input leakage current (VIL)
Output Leakage Current IOH - 50 100 μA Maximum output leakage current (VOH)
Output Leakage Current IOL -100 -50 - μA Maximum output leakage current (VOL)
Propagation Delay Time tpd 20 35 60 ns Propagation delay time from input to output
Power Consumption ICC 0 10 30 μA Quiescent current at no load
Operating Temperature Ta -40 - 85 °C Ambient operating temperature range
Storage Temperature Tstg -65 - 150 °C Storage temperature range

Instructions for Using GD75188

  1. Supply Voltage:

    • Ensure the supply voltage is within the specified range (4.5V to 5.5V). Use a stable power source to avoid voltage fluctuations.
  2. Input Signals:

    • For a valid high input, ensure the voltage is at least 2.0V.
    • For a valid low input, ensure the voltage does not exceed 0.8V.
    • Avoid connecting inputs to voltages outside the VIL and VIH ranges to prevent damage or incorrect operation.
  3. Output Signals:

    • The output will be high (at least 2.4V) when the input is high.
    • The output will be low (no more than 0.4V) when the input is low.
    • Ensure the load connected to the output does not exceed the maximum current ratings (IOH and IOL).
  4. Leakage Current:

    • Be aware of the input and output leakage currents to avoid unexpected behavior in sensitive circuits.
  5. Propagation Delay:

    • Account for the propagation delay time (20ns to 60ns) when designing timing-sensitive circuits.
  6. Power Consumption:

    • The quiescent current (ICC) is typically around 10μA but can vary between 0μA and 30μA. Ensure the power supply can handle this current.
  7. Temperature Considerations:

    • Operate the device within the ambient temperature range (-40°C to 85°C) to ensure reliable performance.
    • Store the device within the storage temperature range (-65°C to 150°C) to prevent damage.
  8. Handling and Installation:

    • Handle the device with care to avoid static discharge, which can damage the internal components.
    • Follow proper soldering techniques to ensure good electrical connections and avoid thermal stress.
  9. Testing:

    • Test the device under typical operating conditions to verify its functionality before integrating it into a larger system.

By following these guidelines, you can ensure optimal performance and reliability of the GD75188 in your electronic designs.

(For reference only)

 Inquiry - GD75188