Specifications
SKU: 11224139
Parameter | Symbol | Conditions | Min | Typical | Max | Unit |
---|---|---|---|---|---|---|
Supply Voltage | VCC | Operating | 2.0 | - | 6.0 | V |
Input Low Voltage | VIL | - | 0.0 | - | 0.8 | V |
Input High Voltage | VIH | - | 2.0 | - | VCC | V |
Output Low Voltage | VOL | IOL = 4 mA | 0.0 | - | 0.4 | V |
Output High Voltage | VOH | IOH = -0.4 mA | 2.4 | - | VCC | V |
Propagation Delay Time (Typical) | tpd | VCC = 5V, TA = 25°C | - | 12 | - | ns |
Power Dissipation | PD | Maximum at TA = 25°C | - | - | 100 | mW |
Operating Temperature Range | TA | - | -40 | - | 85 | °C |
Storage Temperature Range | TSTG | - | -65 | - | 150 | °C |
Instructions for Use:
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 2.0V to 6.0V.
- Connect the ground (GND) pin to a stable 0V reference.
Input Signals:
- Input low voltage (VIL) should be less than or equal to 0.8V.
- Input high voltage (VIH) should be greater than or equal to 2.0V and can go up to VCC.
Output Signals:
- When the output is low, the voltage (VOL) should not exceed 0.4V under a load current of 4mA.
- When the output is high, the voltage (VOH) should be at least 2.4V under a load current of -0.4mA.
Propagation Delay:
- The typical propagation delay time (tpd) is 12ns at VCC = 5V and TA = 25°C.
Power Dissipation:
- The maximum power dissipation (PD) should not exceed 100mW at room temperature (TA = 25°C).
Temperature Ranges:
- The operating temperature range (TA) is from -40°C to 85°C.
- The storage temperature range (TSTG) is from -65°C to 150°C.
Handling and Storage:
- Store the device in a dry environment to prevent moisture damage.
- Handle with care to avoid static discharge, which can damage the device.
Soldering:
- Use appropriate soldering techniques to ensure reliable connections without overheating the device.
Testing:
- Test the device under specified conditions to ensure it meets the performance parameters listed in the table.