Share:


SP483CN

Specifications

SKU: 11224596

BUY SP483CN https://www.utsource.net/itm/p/11224596.html

Below is the parameter table and instructions for the SP483CN, a quad 2-line driver/receiver with 3-state outputs.

SP483CN Parameter Table

Parameter Symbol Min Typ Max Unit Conditions
Supply Voltage VCC 4.75 5.0 5.25 V -
Input Voltage (High) VIH 2.0 - 5.25 V -
Input Voltage (Low) VIL 0 - 0.8 V -
Output Voltage (High) VOH 2.4 - 5.0 V IOL = 4 mA
Output Voltage (Low) VOL 0 - 0.4 V IOL = 16 mA
Output Current (High) IOH - - -4 mA VOH = 2.4 V
Output Current (Low) IOL -16 - - mA VOL = 0.4 V
Propagation Delay Time tpd 0 7 15 ns VCC = 5 V, TA = 25°C
Skew tskew 0 2 5 ns VCC = 5 V, TA = 25°C
Operating Temperature TOP -40 - 85 °C -
Storage Temperature TSTG -65 - 150 °C -

Instructions for Using SP483CN

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 4.75 V to 5.25 V.
    • Connect the ground (GND) pin to the system ground.
  2. Input Signals:

    • Apply input signals (VIH or VIL) to the appropriate input pins.
    • Ensure the input voltages are within the specified ranges to avoid damage or incorrect operation.
  3. Output Signals:

    • The output pins will provide the corresponding high (VOH) or low (VOL) voltages based on the input signals.
    • The output current (IOH and IOL) should be within the specified limits to prevent damage to the device.
  4. Propagation Delay:

    • The propagation delay time (tpd) is the time it takes for the output to respond to a change in the input signal.
    • Ensure that the system timing is designed to accommodate the maximum propagation delay of 15 ns.
  5. Skew:

    • The skew (tskew) is the difference in propagation delay between different channels.
    • Ensure that the system can handle the maximum skew of 5 ns to maintain proper timing.
  6. Temperature Considerations:

    • Operate the device within the operating temperature range of -40°C to 85°C.
    • Store the device within the storage temperature range of -65°C to 150°C.
  7. Handling and Storage:

    • Handle the device with care to avoid static discharge, which can damage the sensitive components.
    • Store the device in a dry and cool environment to prevent moisture damage.

By following these parameters and instructions, you can ensure reliable and efficient operation of the SP483CN in your application.

(For reference only)