Specifications
SKU: 11224596
Below is the parameter table and instructions for the SP483CN, a quad 2-line driver/receiver with 3-state outputs.
SP483CN Parameter Table
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Supply Voltage | VCC | 4.75 | 5.0 | 5.25 | V | - |
Input Voltage (High) | VIH | 2.0 | - | 5.25 | V | - |
Input Voltage (Low) | VIL | 0 | - | 0.8 | V | - |
Output Voltage (High) | VOH | 2.4 | - | 5.0 | V | IOL = 4 mA |
Output Voltage (Low) | VOL | 0 | - | 0.4 | V | IOL = 16 mA |
Output Current (High) | IOH | - | - | -4 | mA | VOH = 2.4 V |
Output Current (Low) | IOL | -16 | - | - | mA | VOL = 0.4 V |
Propagation Delay Time | tpd | 0 | 7 | 15 | ns | VCC = 5 V, TA = 25°C |
Skew | tskew | 0 | 2 | 5 | ns | VCC = 5 V, TA = 25°C |
Operating Temperature | TOP | -40 | - | 85 | °C | - |
Storage Temperature | TSTG | -65 | - | 150 | °C | - |
Instructions for Using SP483CN
Power Supply:
- Ensure the supply voltage (VCC) is within the range of 4.75 V to 5.25 V.
- Connect the ground (GND) pin to the system ground.
Input Signals:
- Apply input signals (VIH or VIL) to the appropriate input pins.
- Ensure the input voltages are within the specified ranges to avoid damage or incorrect operation.
Output Signals:
- The output pins will provide the corresponding high (VOH) or low (VOL) voltages based on the input signals.
- The output current (IOH and IOL) should be within the specified limits to prevent damage to the device.
Propagation Delay:
- The propagation delay time (tpd) is the time it takes for the output to respond to a change in the input signal.
- Ensure that the system timing is designed to accommodate the maximum propagation delay of 15 ns.
Skew:
- The skew (tskew) is the difference in propagation delay between different channels.
- Ensure that the system can handle the maximum skew of 5 ns to maintain proper timing.
Temperature Considerations:
- Operate the device within the operating temperature range of -40°C to 85°C.
- Store the device within the storage temperature range of -65°C to 150°C.
Handling and Storage:
- Handle the device with care to avoid static discharge, which can damage the sensitive components.
- Store the device in a dry and cool environment to prevent moisture damage.
By following these parameters and instructions, you can ensure reliable and efficient operation of the SP483CN in your application.