Share:


HCPL-2631

Specifications

SKU: 11224694

BUY HCPL-2631 https://www.utsource.net/itm/p/11224694.html

Parameter Symbol Min Typical Max Unit Conditions
Forward Voltage VF - 1.2 1.5 V IF = 20 mA
Reverse Voltage VR - - 5 V
Forward Current IF - - 50 mA
Output Current IC - - 50 mA
CTR (Current Transfer Ratio) CTR 100 200 400 % IF = 20 mA, VCE = 5 V
Rise Time tr - 20 50 ns VCC = 5 V, RL = 500 Ω
Fall Time tf - 20 50 ns VCC = 5 V, RL = 500 Ω
Propagation Delay Time td - 25 75 ns VCC = 5 V, RL = 500 Ω
Storage Temperature TSTG -40 - 105 °C
Operating Temperature TA -40 - 85 °C

Instructions for Use:

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the specified range to avoid damage to the device.
    • Recommended operating voltage: 5 V.
  2. Forward Current:

    • Do not exceed the maximum forward current (IF) of 50 mA to prevent overheating and potential failure.
    • For optimal performance, operate at the typical forward current of 20 mA.
  3. Output Current:

    • The maximum output current (IC) should not exceed 50 mA.
    • Ensure the load resistance (RL) is appropriate to maintain this current limit.
  4. CTR (Current Transfer Ratio):

    • The CTR is a critical parameter for ensuring reliable operation. It should be within the range of 100% to 400% for optimal performance.
    • Adjust the input current (IF) to achieve the desired output current (IC).
  5. Timing Parameters:

    • The rise time (tr), fall time (tf), and propagation delay time (td) are important for high-speed applications.
    • Ensure these parameters meet the requirements of your application to avoid signal distortion or timing issues.
  6. Temperature Considerations:

    • The storage temperature (TSTG) ranges from -40°C to 105°C.
    • The operating temperature (TA) should be kept between -40°C and 85°C to ensure reliable performance.
  7. Handling and Storage:

    • Handle the device with care to avoid static discharge and physical damage.
    • Store in a dry, cool place within the specified storage temperature range.
  8. Mounting:

    • Follow the recommended soldering profile and avoid excessive heat during soldering to prevent damage.
    • Ensure proper mechanical support and alignment during installation.
  9. Testing:

    • Before integrating the HCPL-2631 into your circuit, perform initial tests to verify its functionality and parameters.
    • Use appropriate test equipment and conditions as specified in the datasheet.
(For reference only)

 Inquiry - HCPL-2631