Specifications
SKU: 11224705
Parameter | Symbol | Min | Typ | Max | Unit | Conditions |
---|---|---|---|---|---|---|
Forward Voltage | VF | - | 1.2 | 1.5 | V | IF = 20 mA, TA = 25°C |
Peak Forward Current | IF | - | - | 1 A | A | t = 1 ms, Duty Cycle = 1% |
Continuous Forward Current | IF | - | - | 30 | mA | TA = 25°C |
Reverse Voltage | VRRM | - | - | 700 | V | |
Reverse Current | IR | - | 100 | 500 | nA | VR = 400 V, TA = 25°C |
Output Current (Min) | IC | 100 | - | - | mA | IF = 20 mA, TA = 25°C |
Output Current (Max) | IC | - | 500 | - | mA | IF = 20 mA, TA = 25°C |
Isolation Voltage | VI | - | - | 2500 | Vrms | 1 min, 50/60 Hz |
Turn-On Time | ton | - | 2 | 5 | μs | IF = 20 mA, RL = 100 Ω |
Turn-Off Time | toff | - | 2 | 5 | μs | IF = 20 mA, RL = 100 Ω |
Storage Temperature | TSTG | -40 | - | 110 | °C | |
Operating Temperature | TA | -40 | - | 85 | °C |
Instructions for Use:
Mounting and Handling:
- Handle the TLP666JF with care to avoid mechanical stress.
- Ensure proper heat dissipation by mounting on a heatsink if necessary.
Electrical Connections:
- Connect the anode (A) and cathode (K) terminals correctly to the power supply.
- Connect the output terminals (C and E) to the load and ground.
Forward Current:
- Do not exceed the continuous forward current (IF) of 30 mA to prevent overheating.
- For peak currents, ensure that the pulse duration and duty cycle do not exceed the specified limits.
Reverse Voltage:
- The device can withstand a reverse voltage (VRRM) up to 700 V. Ensure that the reverse voltage does not exceed this limit.
Isolation:
- The isolation voltage (VI) is rated at 2500 Vrms for 1 minute at 50/60 Hz. Ensure that the input and output circuits are isolated to prevent electrical shock.
Temperature Considerations:
- Operate the device within the specified temperature range (-40°C to 85°C) to ensure reliable performance.
- Store the device in a dry place within the storage temperature range (-40°C to 110°C).
Timing Parameters:
- The turn-on and turn-off times are critical for proper operation. Ensure that the load resistance (RL) and forward current (IF) are within the specified ranges to achieve the typical timing values.
Testing:
- Before final assembly, test the device under the specified conditions to ensure it meets the required performance parameters.
Compliance:
- Ensure that the device complies with all relevant safety and regulatory standards for the intended application.
Inquiry - TLP666JF