Share:


TLP624-2BV

Specifications

SKU: 11224818

BUY TLP624-2BV https://www.utsource.net/itm/p/11224818.html

Parameter Symbol Min Typ Max Unit Conditions
Forward Voltage VF - 1.2 1.8 V IF = 10 mA
Reverse Breakdown Voltage VBR 50 - - V IR = 1 mA
Forward Current IF - - 30 mA VF ≤ 1.8V
Peak Forward Current IF(peak) - - 100 mA t = 1 ms, duty cycle 1%
Output Voltage VO - 0.5 1.5 V IO = 10 mA
Output Current IO - - 10 mA VO ≤ 1.5V
Isolation Voltage VI - - 2500 Vrms 1 min, 50/60 Hz
Operating Temperature TOP -40 - 110 °C -
Storage Temperature TSTG -40 - 125 °C -

Instructions for TLP624-2BV

  1. Forward Voltage (VF):

    • Ensure that the forward voltage does not exceed 1.8V when the forward current is 10 mA to avoid damaging the device.
  2. Reverse Breakdown Voltage (VBR):

    • The device should not be subjected to reverse voltages greater than 50V to prevent breakdown.
  3. Forward Current (IF):

    • The continuous forward current should not exceed 30 mA to ensure reliable operation.
  4. Peak Forward Current (IF(peak)):

    • The peak forward current can reach up to 100 mA but should be limited to pulses of 1 ms duration with a duty cycle of 1%.
  5. Output Voltage (VO):

    • The output voltage should be kept below 1.5V when the output current is 10 mA to maintain proper functionality.
  6. Output Current (IO):

    • The maximum output current should not exceed 10 mA to avoid overheating or damage.
  7. Isolation Voltage (VI):

    • The isolation voltage between input and output is rated at 2500 Vrms for 1 minute at 50/60 Hz. Ensure this rating is not exceeded to maintain electrical isolation.
  8. Operating Temperature (TOP):

    • The device is designed to operate within a temperature range of -40°C to 110°C. Avoid operating outside this range to prevent performance degradation or failure.
  9. Storage Temperature (TSTG):

    • Store the device in an environment where the temperature ranges from -40°C to 125°C to ensure long-term reliability.
  10. Handling and Installation:

    • Handle the device with care to avoid mechanical stress or damage.
    • Ensure proper soldering techniques are used during installation to prevent thermal shock and ensure good electrical connections.
  11. Electrostatic Discharge (ESD) Protection:

    • Use appropriate ESD protection measures when handling the device to prevent damage from static electricity.
  12. Compliance and Standards:

    • Verify that the device meets all relevant safety and compliance standards for your application.
(For reference only)

 Inquiry - TLP624-2BV