30N60A4D

Specifications

SKU: 11226152

BUY 30N60A4D https://www.utsource.net/itm/p/11226152.html

Parameter Symbol Min Typical Max Unit
Drain-Source Voltage VDS - - 600 V
Gate-Source Voltage VGS -15 - 20 V
Continuous Drain Current ID - - 30 A
Pulse Drain Current IDM - - 90 A
Power Dissipation PD - - 180 W
Junction Temperature TJ -55 - 175 °C
Storage Temperature TSTG -55 - 150 °C
Total Gate Charge QG - 45 - nC
Input Capacitance Ciss - 1900 - pF
Output Capacitance Coss - 300 - pF
Reverse Transfer Capacitance Crss - 250 - pF
On-State Resistance RDS(on) - 0.18 - Ω

Instructions for Use:

  1. Handling Precautions:

    • Handle the 30N60A4D with care to avoid damage to the leads and body.
    • Use proper ESD (Electrostatic Discharge) protection when handling the device to prevent damage from static electricity.
  2. Mounting:

    • Ensure that the mounting surface is clean and flat.
    • Apply thermal paste or a thermal pad between the device and the heatsink to improve heat dissipation.
    • Tighten the mounting screws to the recommended torque to ensure good thermal contact without damaging the device.
  3. Electrical Connections:

    • Connect the drain, source, and gate terminals correctly to avoid short circuits or incorrect operation.
    • Use short, low-inductance leads for high-frequency applications to minimize parasitic effects.
  4. Thermal Management:

    • The maximum junction temperature (TJ) should not exceed 175°C.
    • Ensure adequate cooling, such as a heatsink or forced air cooling, to keep the device within safe operating temperatures.
  5. Gate Drive:

    • The gate-source voltage (VGS) should be kept within the specified range (-15V to +20V).
    • Use a gate resistor to control the switching speed and reduce electromagnetic interference (EMI).
  6. Overcurrent Protection:

    • Implement overcurrent protection to prevent damage due to excessive current.
    • Monitor the drain current (ID) and limit it to the maximum continuous drain current (30A) or pulse drain current (90A) as appropriate.
  7. Storage:

    • Store the device in a dry, cool place away from direct sunlight and sources of heat.
    • Keep the device in its original packaging until ready for use to protect against moisture and physical damage.
  8. Testing:

    • Test the device in a controlled environment to ensure it meets the specified parameters.
    • Use appropriate test equipment and follow safety guidelines to avoid injury or damage to the device.
(For reference only)

 Inquiry - 30N60A4D