Share:


SN74LS04N

Specifications

SKU: 11226662

BUY SN74LS04N https://www.utsource.net/itm/p/11226662.html

Below is the parameter table and instructions for the SN74LS04N hex inverter.

SN74LS04N Parameter Table

Parameter Symbol Min Typ Max Unit Conditions
Supply Voltage VCC 4.75 5.0 5.25 V
Input Voltage (High) VIH 2.0 - 5.0 V
Input Voltage (Low) VIL 0.0 - 0.8 V
Output Voltage (High) VOH 2.4 - 5.0 V IOL = 0.4 mA
Output Voltage (Low) VOL 0.0 - 0.4 V IOL = 16 mA
Input Current (High) IIH - 20 40 μA VI = 5.0 V
Input Current (Low) IIL -1.6 - -0.4 mA VI = 0.0 V
Output Current (High) IOH - -400 -800 μA VO = 2.4 V
Output Current (Low) IOL 8 - 16 mA VO = 0.4 V
Propagation Delay Time tpd - 9 15 ns VCC = 5.0 V, TA = 25°C
Power Dissipation PTOT - - 100 mW Per Package
Operating Temperature Range TA -55 - 125 °C Commercial: 0 to 70°C
Storage Temperature Range TSTG -65 - 150 °C

Instructions for Using SN74LS04N

  1. Power Supply:

    • Connect the VCC pin to a 5V power supply.
    • Connect the GND pin to ground.
  2. Input Connections:

    • Connect the input pins (1, 2, 4, 5, 6, 7) to your logic signals.
    • Ensure that the input voltages are within the specified range (0.0V to 5.0V).
  3. Output Connections:

    • Connect the output pins (3, 4, 8, 9, 10, 11) to your load or subsequent logic circuits.
    • Ensure that the output current does not exceed the maximum ratings (IOH and IOL).
  4. Unused Inputs:

    • If any input pins are not used, they should be tied to either VCC or GND to prevent floating inputs, which can cause unpredictable behavior.
  5. Propagation Delay:

    • The propagation delay time (tpd) is the time it takes for the output to change state after the input changes. This is typically around 9 ns at room temperature.
  6. Temperature Considerations:

    • The device can operate over a wide temperature range (-55°C to 125°C), but for commercial applications, it is typically used between 0°C and 70°C.
  7. Power Dissipation:

    • Ensure that the total power dissipation does not exceed 100 mW to avoid overheating.
  8. Storage:

    • Store the device in a dry, cool place within the specified storage temperature range (-65°C to 150°C).

By following these instructions, you can ensure reliable operation of the SN74LS04N hex inverter in your circuit.

(For reference only)