Share:


TC5020BP

Specifications

SKU: 11226673

BUY TC5020BP https://www.utsource.net/itm/p/11226673.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage Vcc Operating 4.5 5.0 5.5 V
Output Current Iout Continuous - 200 - mA
Quiescent Current Iq No load - 1.5 3.0 mA
Dropout Voltage Vdo Iout = 100mA - 0.6 1.2 V
Line Regulation ΔVout/ΔVin Iout = 100mA, Vcc from 4.5V to 5.5V - 0.01 0.03 %
Load Regulation ΔVout/ΔIout Vin = 5V, Iout from 0 to 200mA - 0.05 0.15 %
Ripple Rejection RR 1kHz - 70 80 dB
Thermal Shutdown TSD Operating - 150 170 °C
Operating Temperature Topr Operating -40 - 85 °C
Storage Temperature Tstg Non-operating -65 - 150 °C

Instructions for Use:

  1. Supply Voltage (Vcc):

    • Ensure the supply voltage is within the range of 4.5V to 5.5V to avoid damage to the device.
  2. Output Current (Iout):

    • The device can provide up to 200mA of continuous output current. Exceeding this limit may cause overheating or damage.
  3. Quiescent Current (Iq):

    • The quiescent current is typically around 1.5mA with no load. This should be considered in low-power applications.
  4. Dropout Voltage (Vdo):

    • The dropout voltage is the minimum difference between the input and output voltages required to maintain regulation. It is typically 0.6V at 100mA output current.
  5. Line Regulation:

    • The line regulation is the change in output voltage due to changes in input voltage. It is typically 0.01% to 0.03% over the operating range.
  6. Load Regulation:

    • The load regulation is the change in output voltage due to changes in load current. It is typically 0.05% to 0.15% over the operating range.
  7. Ripple Rejection (RR):

    • The device provides good ripple rejection, typically 70dB to 80dB at 1kHz, which helps in filtering out noise from the input supply.
  8. Thermal Shutdown (TSD):

    • The device includes thermal shutdown protection, which activates at temperatures between 150°C and 170°C to prevent damage from overheating.
  9. Operating Temperature (Topr):

    • The device is designed to operate within a temperature range of -40°C to 85°C. Ensure that the ambient temperature does not exceed these limits.
  10. Storage Temperature (Tstg):

    • When the device is not in use, store it in an environment where the temperature ranges from -65°C to 150°C.

Additional Notes:

  • PCB Layout:
    • Use a proper PCB layout with adequate copper areas for heat dissipation.
  • Capacitors:
    • Place input and output capacitors close to the device to ensure stability and reduce noise.
  • Heat Sinking:
    • For high current applications, consider using a heatsink to improve thermal performance.

By following these guidelines, you can ensure optimal performance and reliability of the TC5020BP in your application.

(For reference only)

 Inquiry - TC5020BP