Specifications
SKU: 11228242
Parameter | Symbol | Min | Typical | Max | Unit | Notes |
---|---|---|---|---|---|---|
Input Voltage | VIN | 4.5 | - | 18 | V | |
Output Voltage | VOUT | 1.2 | - | 5.0 | V | Adjustable |
Output Current | IOUT | - | 15 | - | A | Continuous |
Efficiency | η | - | 93 | - | % | At full load |
Switching Frequency | fSW | - | 600 | - | kHz | |
Quiescent Current | IQ | - | 2.5 | - | mA | Shutdown mode |
Shutdown Current | ISD | - | 0.1 | - | μA | |
Operating Temperature | TOPR | -40 | - | 125 | °C | |
Storage Temperature | TSTG | -40 | - | 150 | °C | |
Thermal Resistance | θJA | - | 40 | - | °C/W | Junction to ambient |
Instructions for Use:
Input Connection:
- Connect the input voltage (VIN) to the input pin of the FCH20A15. Ensure the input voltage is within the specified range of 4.5V to 18V.
Output Configuration:
- Set the output voltage (VOUT) by adjusting the external resistor network connected to the feedback (FB) pin. Refer to the datasheet for specific resistor values.
Output Load:
- The FCH20A15 can provide up to 15A of continuous output current. Ensure that the load does not exceed this limit to avoid overheating or damage.
Thermal Management:
- Place the FCH20A15 on a suitable heatsink or PCB with adequate copper area to ensure proper heat dissipation. The thermal resistance (θJA) should be considered to maintain the operating temperature within safe limits.
Efficiency:
- The efficiency of the FCH20A15 is typically around 93% at full load. Monitor the efficiency under different load conditions to optimize performance.
Shutdown Mode:
- To enter shutdown mode, pull the enable (EN) pin low. The quiescent current will drop to 0.1μA in this mode.
Operating and Storage Temperature:
- The device can operate in temperatures ranging from -40°C to 125°C and can be stored between -40°C and 150°C.
PCB Layout:
- Follow good PCB layout practices to minimize noise and parasitic effects. Keep input and output capacitors close to the device and use wide traces for power paths.
Capacitor Selection:
- Choose input and output capacitors with appropriate ratings and low ESR to ensure stable operation. Refer to the datasheet for recommended capacitor types and values.
Safety Precautions:
- Always follow safety guidelines when handling high voltages and currents. Ensure proper insulation and grounding to prevent electrical hazards.
For more detailed information, refer to the FCH20A15 datasheet and application notes provided by the manufacturer.
(For reference only)Inquiry - FCH20A15