Specifications
SKU: 11232589
Parameter | Symbol | Test Conditions | Min | Typ | Max | Unit |
---|---|---|---|---|---|---|
Drain-Source Voltage | VDS | - | 55 | - | V | |
Gate-Source Voltage | VGS | -10 | 0 | 20 | V | |
Continuous Drain Current | ID | TC = 25°C | - | 12 | - | A |
TC = 75°C | - | 8.4 | - | A | ||
Pulse Drain Current | ID(p) | tp = 10 μs, TC = 25°C | - | 36 | - | A |
RDS(on) at VGS = 10V | RDS(on) | ID = 5A, TC = 25°C | - | 0.014 | - | Ω |
ID = 5A, TC = 100°C | - | 0.020 | - | Ω | ||
Gate Charge | QG | VDS = 25V, ID = 5A | - | 20 | - | nC |
Total Gate Charge | QGT | VDS = 25V, ID = 5A | - | 33 | - | nC |
Input Capacitance | Ciss | VDS = 25V, f = 1 MHz | - | 1400 | - | pF |
Output Capacitance | Coss | VDS = 25V, f = 1 MHz | - | 420 | - | pF |
Reverse Transfer Capacitance | Crss | VDS = 25V, f = 1 MHz | - | 350 | - | pF |
Junction Temperature | TJ | -55 | - | 150 | °C | |
Storage Temperature | TSTG | -55 | - | 150 | °C |
Instructions for Use:
Handling Precautions:
- The IRFS4229PBF is sensitive to electrostatic discharge (ESD). Use appropriate ESD protection measures when handling the device.
- Avoid exposing the device to excessive mechanical stress or thermal shock.
Mounting:
- Ensure proper heat sinking to maintain the junction temperature within the specified limits.
- Use a flat and clean surface for mounting to ensure good thermal contact.
Operating Conditions:
- Do not exceed the maximum ratings listed in the table.
- Ensure that the gate-source voltage (VGS) is within the specified range to avoid damage to the gate oxide.
Driving the Gate:
- Use a low impedance driver to minimize switching times and reduce switching losses.
- Ensure the gate drive circuit can provide sufficient current to charge and discharge the gate capacitance quickly.
Thermal Management:
- Monitor the junction temperature during operation to prevent overheating.
- Consider using forced air cooling or a heatsink with adequate thermal resistance.
Storage:
- Store the device in a dry, cool place to prevent moisture absorption and degradation.
- Follow the recommended storage conditions to ensure long-term reliability.
Testing:
- Use the test conditions specified in the table for accurate characterization and testing of the device.
- Ensure that all test equipment is calibrated and capable of measuring the parameters accurately.
By following these instructions, you can ensure optimal performance and reliability of the IRFS4229PBF in your application.