Specifications
SKU: 11232855
Parameter | Symbol | Min | Typical | Max | Unit | Condition |
---|---|---|---|---|---|---|
Input Voltage | VIN | 2.7 | - | 5.5 | V | - |
Output Voltage | VOUT | - | 3.3 | - | V | Fixed |
Output Current | IOUT | - | - | 1.5 | A | Continuous |
Quiescent Current | IQ | - | 2.5 | - | μA | No load, VIN = 3.3V |
Dropout Voltage | VDROP | - | 0.3 | - | V | IOUT = 1.5A |
Load Regulation | - | - | 0.5 | - | % | 0mA to 1.5A |
Line Regulation | - | - | 0.1 | - | %/V | 2.7V to 5.5V |
Ripple Rejection | - | - | 60 | - | dB | 100Hz to 100kHz |
Operating Temperature | TOP | -40 | - | 85 | °C | - |
Storage Temperature | TSTG | -55 | - | 150 | °C | - |
Instructions for Use:
Input Connection:
- Connect the input voltage (VIN) to the input pin of the HUF75645P3.
- Ensure the input voltage is within the range of 2.7V to 5.5V.
Output Connection:
- Connect the output pin to the load or circuit requiring a stable 3.3V supply.
- The maximum continuous output current is 1.5A.
Ground Connection:
- Connect the ground (GND) pin to the common ground of the system.
Capacitors:
- Place a 1μF ceramic capacitor close to the input pin to stabilize the input voltage.
- Place a 1μF ceramic capacitor close to the output pin to filter the output and reduce ripple.
Thermal Management:
- Ensure adequate heat dissipation if operating at high output currents or in high ambient temperatures.
- The device can operate up to 85°C, but performance may degrade at higher temperatures.
Storage:
- Store the device in a dry environment with temperatures between -55°C and 150°C.
Handling:
- Handle the device with care to avoid static damage.
- Follow proper ESD (Electrostatic Discharge) precautions when handling and installing the device.
Inquiry - HUF75645P3