Share:


STP8NM50FP,P8NM50FP

Specifications

SKU: 11233396

BUY STP8NM50FP,P8NM50FP https://www.utsource.net/itm/p/11233396.html

Parameter Symbol Min Typ Max Unit Notes
Drain-Source Voltage VDS - 500 - V
Gate-Source Voltage VGS -20 - 20 V
Continuous Drain Current ID - 8 - A @ TC = 25°C
Pulse Drain Current IDpeak - 32 - A @ TC = 25°C, tp = 10 μs, Duty Cycle = 1%
Total Power Dissipation PTOT - - 77 W @ TC = 25°C
Junction Temperature TJ - - 150 °C
Storage Temperature Range TSTG -65 - 150 °C
Gate Charge QG - 12 - nC @ VGS = 10V, VDS = 250V, ID = 8A
Input Capacitance Ciss - 1100 - pF @ VDS = 250V, f = 1 MHz
Output Capacitance Coss - 220 - pF @ VDS = 250V, f = 1 MHz
Reverse Transfer Capacitance Crss - 240 - pF @ VDS = 250V, f = 1 MHz
On-State Resistance RDS(on) - 0.95 - Ω @ VGS = 10V, ID = 8A, TJ = 25°C

Instructions for Use:

  1. Mounting and Handling:

    • Ensure that the device is handled with care to avoid damage to the pins and the die.
    • Use appropriate anti-static precautions to prevent electrostatic discharge (ESD) damage.
  2. Thermal Management:

    • The device should be mounted on a heatsink or other cooling solution to maintain the junction temperature within the specified limits.
    • Ensure adequate airflow around the device to enhance heat dissipation.
  3. Biasing and Drive:

    • Apply the gate-source voltage (VGS) within the specified range to ensure reliable operation.
    • Use a gate resistor to control the switching speed and reduce EMI.
  4. Overcurrent Protection:

    • Implement overcurrent protection to prevent damage from excessive drain current.
    • Consider using a current-limiting circuit or a fuse in series with the drain.
  5. Reverse Voltage Protection:

    • The device is not designed to block reverse voltage. Ensure that the polarity of the applied voltage is correct to avoid damage.
  6. Storage and Operating Conditions:

    • Store the device in a dry, cool place within the specified storage temperature range.
    • Operate the device within the specified operating temperature range to ensure reliability and longevity.
  7. Testing and Troubleshooting:

    • Use a multimeter or an oscilloscope to verify the correct operation of the device.
    • Check for proper biasing and cooling during testing.
  8. Compliance and Standards:

    • Ensure that the device complies with relevant safety and regulatory standards for your application.

For detailed application notes and further information, refer to the datasheet provided by STMicroelectronics.

(For reference only)

 Inquiry - STP8NM50FP,P8NM50FP