Parameter Symbol Value Unit
Maximum Drain-Source Voltage VDS(max) 600 V
Maximum Gate-Source Voltage VGS(max) ±20 V
Continuous Drain Current (TC = 25°C) ID(25°C) 4.0 A
Continuous Drain Current (TC = 100°C) ID(100°C) 2.8 A
Pulse Drain Current (tp = 10 μs, IGM = 10 A) IDpeak 16.0 A
Total Power Dissipation (TC = 25°C) PTOT(25°C) 120 W
Total Power Dissipation (TC = 100°C) PTOT(100°C) 70 W
Junction Temperature Range TJ -55 to 150 °C
Storage Temperature Range TSTG -55 to 150 °C
Thermal Resistance, Junction to Case RθJC 1.5 °C/W
Gate Charge at VGS = 15 V, ID = 4 A QG 40 nC
Input Capacitance at VDS = 400 V, VGS = 0 V Ciss 1100 pF
Output Capacitance at VDS = 400 V, VGS = 0 V Coss 220 pF

Instructions for Use:

  1. Handling Precautions:

    • Avoid exposing the device to static electricity.
    • Handle with care to prevent mechanical damage.
  2. Mounting:

    • Ensure proper heat sinking to manage thermal resistance.
    • Use appropriate mounting hardware and thermal compound to enhance heat dissipation.
  3. Electrical Connections:

    • Connect the drain (D), gate (G), and source (S) terminals correctly.
    • Ensure that the gate-source voltage does not exceed the maximum rating to avoid damage.
  4. Operating Conditions:

    • Operate within the specified temperature range to ensure reliable performance.
    • Monitor the junction temperature to prevent overheating.
  5. Pulse Operation:

    • For pulse applications, ensure that the pulse duration and current do not exceed the rated values.
  6. Storage:

    • Store the device in a dry, cool place away from direct sunlight and corrosive environments.
  7. Testing:

    • Use appropriate test equipment and methods to verify the device parameters.
    • Follow safety guidelines when testing high-voltage components.
  8. Derating:

    • Derate the continuous drain current and power dissipation as per the derating curve provided in the datasheet for temperatures above 25°C.
  9. Documentation:

    • Refer to the full datasheet for detailed specifications and application notes.
(For reference only)