Share:


FGH60N60SFD

Specifications

SKU: 11240841

BUY FGH60N60SFD https://www.utsource.net/itm/p/11240841.html

Parameter Symbol Min Typical Max Unit
Drain-Source Voltage VDS - 600 - V
Gate-Source Voltage VGS -20 - 20 V
Continuous Drain Current (TC = 25°C) ID - 60 - A
Continuous Drain Current (TC = 100°C) ID - 40 - A
Pulse Drain Current (tp = 10 μs, IGM = 10 A) IDm - 180 - A
Total Power Dissipation (TC = 25°C) PTOT - 360 - W
Total Power Dissipation (TC = 100°C) PTOT - 240 - W
Junction Temperature TJ - - 175 °C
Storage Temperature Range TSTG -55 - 150 °C
Thermal Resistance, Junction to Case RthJC - 0.5 - °C/W
Thermal Resistance, Junction to Ambient RthJA - 2.5 - °C/W

Instructions for Use:

  1. Handling Precautions:

    • ESD Sensitivity: The FGH60N60SFD is sensitive to electrostatic discharge (ESD). Handle with care and use proper ESD protection.
    • Storage: Store in a dry, cool place away from direct sunlight and corrosive substances.
  2. Mounting:

    • Heat Sinking: Ensure adequate heat sinking to maintain junction temperature within safe limits. Use thermal paste between the device and the heatsink for better thermal conductivity.
    • Mechanical Stress: Avoid applying excessive mechanical stress to the leads or body of the device during mounting.
  3. Electrical Connections:

    • Gate Drive: Apply gate drive voltages within the specified range to avoid damage. A typical gate drive voltage is +15V for turn-on and -5V for turn-off.
    • Drain-Source Voltage: Do not exceed the maximum drain-source voltage (600V) to prevent breakdown.
    • Current Limiting: Use current-limiting resistors or other methods to ensure the continuous drain current does not exceed the rated values.
  4. Operating Conditions:

    • Temperature: Operate the device within the specified temperature range to ensure reliable performance and longevity.
    • Power Dissipation: Monitor power dissipation to avoid exceeding the maximum ratings. Use appropriate cooling solutions if necessary.
  5. Testing:

    • Initial Testing: Perform initial testing at low power levels to verify correct operation before moving to full load conditions.
    • Regular Inspections: Conduct regular inspections to check for signs of wear or damage, especially in high-stress applications.
  6. Safety:

    • Isolation: Ensure proper isolation and grounding to prevent electrical hazards.
    • Compliance: Adhere to all relevant safety standards and regulations when designing and using circuits with the FGH60N60SFD.

For more detailed information, refer to the datasheet provided by the manufacturer.

(For reference only)

 Inquiry - FGH60N60SFD