Share:


MC14503BCP

Specifications

SKU: 11242664

BUY MC14503BCP https://www.utsource.net/itm/p/11242664.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC - 2.0 5.0 6.0 V
Input Voltage (High Level) VIH II = -0.1 mA 2.0 5.0 - V
Input Voltage (Low Level) VIL II = 0.1 mA - 0.8 1.5 V
Output Voltage (High Level) VOH IO = -0.1 mA 2.4 5.0 - V
Output Voltage (Low Level) VOL IO = 0.1 mA - 0.4 0.5 V
Input Current (High Level) IIH VI = VCC -0.1 - - mA
Input Current (Low Level) IIL VI = 0 V - - 0.1 mA
Output Current (High Level) IOH VO = VCC - 1.5 V - - 0.1 mA
Output Current (Low Level) IOL VO = 0.4 V - - 0.1 mA
Propagation Delay Time tpd VCC = 5 V, TA = 25°C 15 25 35 ns
Power Dissipation PD - - 100 - mW
Operating Temperature Range TA - -40 25 85 °C
Storage Temperature Range TSTG - -65 - 150 °C

Instructions for Using the MC14503BCP

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the specified range of 2.0 V to 6.0 V.
    • Connect the ground (GND) pin to a stable reference point.
  2. Input Signals:

    • Apply input voltages (VIH and VIL) that meet the specified levels to ensure proper logic levels.
    • Keep input currents within the specified limits to avoid damage to the device.
  3. Output Signals:

    • Ensure that the output voltages (VOH and VOL) are within the specified ranges for high and low states.
    • Limit the output currents (IOH and IOL) to prevent overloading the device.
  4. Propagation Delay:

    • Account for the propagation delay time (tpd) in your timing calculations to ensure reliable operation.
  5. Temperature Considerations:

    • Operate the device within the specified operating temperature range (TA) to maintain performance and reliability.
    • Store the device within the storage temperature range (TSTG) to prevent damage during non-operational periods.
  6. Power Dissipation:

    • Ensure that the power dissipation (PD) does not exceed the maximum rating to avoid overheating and potential failure.
  7. Handling:

    • Handle the device with care to avoid static discharge, which can damage sensitive components.
    • Follow standard ESD (Electrostatic Discharge) precautions when handling and installing the device.
(For reference only)

 Inquiry - MC14503BCP