Share:


ICL7107CPLZ

Specifications

SKU: 11243417

BUY ICL7107CPLZ https://www.utsource.net/itm/p/11243417.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating 2.2 - 6 V
Reference Voltage VREF Internal 0.3 0.5 0.7 V
Input Voltage Range VIN Differential - - 2VREF V
Input Bias Current IB VIN = 0V - 10 - pA
Zero Error EZERO VIN = 0V - 0.1 0.5 mV
Linearity Error ELIN Full Scale - 0.01 0.05 %
Conversion Time tC 100mV Step, 2.5V to 2.6V - 100 200 ms
Power Consumption Ptot All Segments Lit - 15 20 mW
Operating Temperature Range TOP Commercial 0 - 70 °C
Storage Temperature Range TSTG -40 - 85 °C

Instructions for Using the ICL7107CPLZ

  1. Power Supply:

    • Connect the supply voltage (VCC) between 2.2V and 6V.
    • Ensure a stable power supply to avoid fluctuations that can affect performance.
  2. Reference Voltage:

    • The internal reference voltage is approximately 0.5V. For precise applications, an external reference can be used.
  3. Input Signal:

    • The differential input voltage range should not exceed 2 times the reference voltage (2VREF).
    • Ensure the input bias current is within the specified limits to avoid errors.
  4. Zero and Linearity Errors:

    • Calibrate the device to minimize zero error (EZERO) and linearity error (ELIN).
    • Use calibration procedures as per the datasheet to achieve optimal accuracy.
  5. Conversion Time:

    • The conversion time for a 100mV step from 2.5V to 2.6V is typically 100ms to 200ms.
    • Allow sufficient time for the ADC to complete conversions.
  6. Power Consumption:

    • When all segments are lit, the power consumption is typically 15mW to 20mW.
    • Consider this when designing the power supply and thermal management.
  7. Temperature Range:

    • Operate the device within the commercial temperature range of 0°C to 70°C.
    • Store the device between -40°C and 85°C to ensure long-term reliability.
  8. Handling and Storage:

    • Handle the device with care to avoid static damage.
    • Store in a dry, cool place to prevent moisture-related issues.
  9. Application Notes:

    • Refer to the application notes and datasheet for detailed information on specific use cases and advanced configurations.

By following these guidelines, you can ensure optimal performance and reliability of the ICL7107CPLZ in your electronic designs.

(For reference only)

 Inquiry - ICL7107CPLZ