Share:


FSL106HR

Specifications

SKU: 11244351

BUY FSL106HR https://www.utsource.net/itm/p/11244351.html

Parameter Symbol Min Typical Max Unit Description
Input Voltage VIN 2.7 - 5.5 V Operating input voltage range
Output Voltage VOUT - 3.3 - V Fixed output voltage
Output Current IOUT - 600 - mA Maximum continuous output current
Quiescent Current IQ - 2.5 - μA Quiescent current
Dropout Voltage VD - 200 - mV Dropout voltage at IOUT = 300mA
Load Regulation - - 1.5 - % Load regulation from 0 to 600mA
Line Regulation - - 0.05 - %/V Line regulation over input range
Ripple Rejection - - 60 - dB Ripple rejection at 100Hz
Thermal Shutdown - - 160 - °C Thermal shutdown temperature
Operating Temperature Toper -40 - 125 °C Operating temperature range
Storage Temperature Tstg -65 - 150 °C Storage temperature range

Instructions for Use:

  1. Input Voltage (VIN):

    • Ensure the input voltage is within the specified range of 2.7V to 5.5V.
    • Do not exceed the maximum input voltage to avoid damage to the device.
  2. Output Voltage (VOUT):

    • The FSL106HR provides a fixed output voltage of 3.3V.
    • Verify that the load can operate with this voltage level.
  3. Output Current (IOUT):

    • The device can supply up to 600mA continuously.
    • For higher current requirements, consider using a different regulator or additional cooling measures.
  4. Quiescent Current (IQ):

    • The quiescent current is very low at 2.5μA, making the device suitable for battery-powered applications.
  5. Dropout Voltage (VD):

    • The dropout voltage is 200mV at 300mA. Ensure the input voltage is at least 200mV higher than the output voltage to maintain regulation.
  6. Load and Line Regulation:

    • The load regulation is 1.5% from 0 to 600mA, and the line regulation is 0.05%/V.
    • These parameters ensure stable output voltage under varying load and input conditions.
  7. Ripple Rejection:

    • The device has a ripple rejection of 60dB at 100Hz, which helps in reducing output noise.
  8. Thermal Management:

    • The thermal shutdown temperature is 160°C. Ensure proper heat dissipation to prevent overheating.
    • Use a heatsink if operating at high temperatures or high current levels.
  9. Operating and Storage Temperature:

    • The device operates within a temperature range of -40°C to 125°C and can be stored between -65°C and 150°C.
  10. Mounting and Handling:

    • Follow standard handling and mounting procedures for surface mount devices.
    • Avoid excessive mechanical stress during soldering and assembly.
  11. Capacitor Selection:

    • Use appropriate input and output capacitors to stabilize the circuit and reduce ripple.
    • Recommended values are typically 1μF ceramic capacitors for both input and output.
  12. PCB Layout:

    • Place the input and output capacitors as close as possible to the regulator to minimize inductance and improve stability.
    • Ensure good ground connections and proper PCB layout to reduce noise and interference.
(For reference only)

 Inquiry - FSL106HR