Specifications
SKU: 11244858
TVS Diode
Parameter | Symbol | Min | Typ | Max | Unit | Notes |
---|---|---|---|---|---|---|
Reverse Standoff Voltage | VRWM | - | 91 | - | V | |
Maximum Clamping Voltage | VC | - | 145 | - | V | @ Ipp = 1A |
Peak Pulse Current | Ipp | - | - | 20 | A | @ tP = 8.3/400μs |
Maximum Reverse Leakage Current | IR | - | 1 | - | μA | @ VRWM = 91V, 25°C |
Capacitance | C | - | 270 | - | pF | @ 1MHz, VRWM = 91V |
Operating Temperature Range | Toper | -55 | - | 150 | °C | |
Storage Temperature Range | Tstg | -55 | - | 150 | °C | |
Mounting Type | - | - | - | - | Surface Mount | |
Package | - | - | - | - | DO-214AC (SMA) |
Instructions:
- Mounting: Ensure the device is mounted on a PCB with proper soldering to ensure good electrical and thermal connections.
- Voltage Handling: The P6KE91CA is designed to handle reverse standoff voltages up to 91V. Ensure that the operating voltage does not exceed this limit to avoid damage.
- Pulse Current: The device can handle peak pulse currents up to 20A for short durations (8.3/400μs). Avoid continuous exposure to high currents to prevent overheating and failure.
- Leakage Current: Monitor the reverse leakage current, which should not exceed 1μA at the rated reverse standoff voltage and room temperature.
- Temperature Management: Operate the device within the specified temperature range (-55°C to 150°C). Exceeding these limits can lead to reduced performance or failure.
- Capacitance Consideration: The capacitance of 270pF at 1MHz should be considered when designing circuits, especially in high-frequency applications.
- Storage: Store the device in a dry, cool environment within the storage temperature range to maintain its performance characteristics.
- Handling: Use appropriate ESD protection measures when handling the device to prevent damage from static electricity.
Inquiry - P6KE91CA