Specifications

SKU: 11247290

BUY 74F245 https://www.utsource.net/itm/p/11247290.html

Parameter Symbol Min Typ Max Unit Conditions
Supply Voltage VCC 4.5 5.0 5.5 V
Output High-Level Voltage VOH 2.7 3.5 5.0 V IOL = -1.6 mA
Output Low-Level Voltage VOL 0.0 0.4 0.5 V IOH = 8 mA
Input Leakage Current II -1 0 1 μA VI = 0 V to VCC
Output Leakage Current IO -1 0 1 μA VO = 0 V to VCC
Propagation Delay Time tpd 5 8 ns VCC = 5 V, TA = 25°C
Power Dissipation PD 200 mW Per Package
Operating Temperature TOPR -40 85 °C
Storage Temperature TSTG -65 150 °C

Instructions for Using 74F245 Octal Bus Transceiver

  1. Power Supply:

    • Connect VCC (pin 20) to +5V and GND (pin 10) to ground.
    • Ensure that the power supply is stable and within the specified range to avoid damage to the device.
  2. Direction Control:

    • The direction of data transfer is controlled by the DIR pin (pin 1).
    • When DIR is high, data flows from A to B.
    • When DIR is low, data flows from B to A.
  3. Enable Control:

    • The OE (Output Enable) pin (pin 19) controls whether the outputs are active or in high-impedance state.
    • When OE is high, the outputs are in high-impedance state.
    • When OE is low, the outputs are active and can drive the bus.
  4. Data Inputs and Outputs:

    • Data inputs are on pins A1 to A8 (pins 2 to 9).
    • Data outputs are on pins B1 to B8 (pins 11 to 18).
  5. Bus Isolation:

    • When OE is high, both sets of outputs (B1 to B8 and A1 to A8) are in high-impedance state, isolating the bus.
  6. Propagation Delay:

    • The propagation delay time (tpd) is the time it takes for a change in the input to be reflected at the output. It is typically around 5 ns at VCC = 5V and 25°C.
  7. Temperature Considerations:

    • The operating temperature range is -40°C to 85°C. Ensure that the device operates within this range to maintain reliability.
    • The storage temperature range is -65°C to 150°C.
  8. Power Dissipation:

    • The maximum power dissipation per package is 200 mW. Ensure proper heat dissipation if the device is used in high-power applications.
  9. Handling Precautions:

    • Handle the device with care to avoid static discharge, which can damage the internal circuits.
    • Use proper anti-static precautions when handling and installing the device.
  10. Testing and Verification:

    • After installation, verify the functionality of the device by testing the data transfer in both directions (A to B and B to A) and ensuring that the outputs are correctly enabled and disabled based on the OE and DIR signals.
(For reference only)