AT25SF081-SSHD-T

Specifications

SKU: 11249078

BUY AT25SF081-SSHD-T https://www.utsource.net/itm/p/11249078.html

Parameter Symbol Conditions Min Typ Max Unit
Supply Voltage VCC Operating 2.7 - 3.6 V
Standby Current ICC(STANDBY) VCC = 3.0V - 1 - μA
Active Current ICC(ACTIVE) VCC = 3.0V, Read - 4 - mA
Programming Current IPROG VCC = 3.0V, Write - 2 5 mA
Data Retention Time tRET - - - 100 Years
Page Program Time tPP - - 3 5 ms
Sector Erase Time tSE - - 200 300 ms
Bulk Erase Time tBE - - 2000 3000 ms
Data Output High Level VOH IO = -0.4mA, VCC = 3.0V 2.4 - - V
Data Output Low Level VOL IO = 0.4mA, VCC = 3.0V - - 0.4 V
Input High Voltage VIH - 2.0 - VCC V
Input Low Voltage VIL - 0 - 0.8 V

Instructions for Use

  1. Power Supply:

    • Ensure the supply voltage (VCC) is within the range of 2.7V to 3.6V.
    • The device has a low standby current of 1μA at 3.0V, making it suitable for battery-powered applications.
  2. Current Consumption:

    • During active operations (e.g., reading), the current consumption is typically 4mA at 3.0V.
    • When programming, the current can range from 2mA to 5mA at 3.0V.
  3. Data Retention:

    • The device guarantees data retention for up to 100 years under normal operating conditions.
  4. Programming and Erasing:

    • Page program time is typically 3ms and can take up to 5ms.
    • Sector erase time is typically 200ms and can take up to 300ms.
    • Bulk erase time is typically 2000ms and can take up to 3000ms.
  5. Input/Output Levels:

    • Ensure that the data output high level (VOH) is at least 2.4V when IO = -0.4mA and VCC = 3.0V.
    • The data output low level (VOL) should not exceed 0.4V when IO = 0.4mA and VCC = 3.0V.
    • Input high voltage (VIH) should be at least 2.0V and can go up to VCC.
    • Input low voltage (VIL) should be between 0V and 0.8V.
  6. Handling:

    • Handle the device with care to avoid electrostatic discharge (ESD) damage.
    • Store the device in a dry environment to prevent moisture-related issues.
  7. Programming and Configuration:

    • Refer to the device datasheet for specific commands and protocols for programming and configuring the memory.
    • Use appropriate software tools or hardware interfaces to communicate with the device.
  8. Environmental Considerations:

    • Operate the device within the specified temperature range to ensure reliable performance.
    • Avoid exposing the device to extreme temperatures, humidity, or mechanical stress.

For detailed information on specific commands and operational sequences, refer to the AT25SF081-SSHD-T datasheet provided by Atmel.

(For reference only)

 Inquiry - AT25SF081-SSHD-T