Specifications
SKU: 11249591
Parameter | Description | Min | Typ | Max | Unit |
---|---|---|---|---|---|
VDD | Supply Voltage | 3 | - | 18 | V |
IDD | Supply Current (per channel) | - | - | 1 | μA |
VOH | Output High Level Voltage | 2.4 | - | VDD - 0.1 | V |
VOL | Output Low Level Voltage | 0 | - | 0.1 | V |
IOH | Output High Level Current | - | - | -1 | mA |
IOL | Output Low Level Current | - | - | 1 | mA |
VIH | Input High Level Voltage | 2 | - | VDD | V |
VIL | Input Low Level Voltage | 0 | - | 0.8 | V |
IIN | Input Leakage Current | - | - | ±1 | nA |
tpd | Propagation Delay Time | - | 10 | 40 | ns |
tphl | High to Low Propagation Delay | - | 10 | 40 | ns |
tplh | Low to High Propagation Delay | - | 10 | 40 | ns |
Operating Temperature Range | - | -40 | - | 85 | °C |
Storage Temperature Range | - | -65 | - | 150 | °C |
Instructions for Using the HEF4066BT+653
Power Supply:
- Ensure the supply voltage (VDD) is within the range of 3V to 18V.
- Connect the VDD pin to the positive supply and the GND pin to the ground.
Input Signals:
- Apply input signals (VIN) within the specified levels (0V to VDD).
- Ensure the input signals do not exceed the supply voltage to avoid damage.
Output Signals:
- The output signals (VOUT) will be either high (VOH) or low (VOL) based on the control signals.
- The output current should not exceed the maximum ratings (IOH and IOL).
Control Signals:
- Use the control inputs (C1, C2, C3, C4) to enable or disable the corresponding bilateral switches.
- A high level on the control input enables the switch, while a low level disables it.
Propagation Delay:
- The propagation delay (tpd) is the time it takes for the output to respond to a change in the input signal.
- Ensure that the system design accounts for the propagation delay to avoid timing issues.
Temperature Considerations:
- Operate the device within the specified temperature range (-40°C to 85°C) to ensure reliable performance.
- Store the device within the storage temperature range (-65°C to 150°C) to prevent damage.
Handling and Storage:
- Handle the device with care to avoid static discharge, which can damage the internal circuits.
- Store the device in a dry and cool environment to prevent moisture damage.
Testing and Troubleshooting:
- Use a multimeter to check the supply voltage and ensure it is within the specified range.
- Verify the input and output signals using an oscilloscope to ensure they meet the required levels and timing.
- If the device does not function as expected, check for any short circuits or open connections in the circuit.
Inquiry - HEF4066BT+653